Use and Care
............ www.truemfg.com ............
1919
True Food Service Equipment, Inc.
1
2
3
4
LAE Electronic Control
Info/Set Point
Button
Manual Defrost/
Down Button
Manual Activation/
Up Button
Stand-By
Button
Compressor
Running
Activation of 2nd
Parameter Set - NA
Alarm - NA
Cabinet in Defrost
Evaporator Fan
Running
LAE Control Icons
WHY:
THE DEFROST INTERVAL IS THE TIME DURATION BETWEEN
DEFROST CYCLES.
The Defrost Interval time starts when the cabinet is supplied
power or after a manual defrost.
HOW:
A. Toseethesetpoint,pressandholdtheinfobutton
andthestand-bybuttonatthesametime.
“ScL”willappear.Seeimage1.
B. Pushtheupbuttonuntil“dFt”appears.
Seeimage2.
C. Pressandholdtheinfobuttontoseethe
“defrostintervaltime”.Seeimage3.
D. Whilepressingandholdingtheinfobutton,
presstheupordownbuttontochangethe“defrost
intervaltimes”(higherthenumberthelessfrequentthe
cabinetwilldefrost).
E. Oncethe“defrostintervaltime”hasbeenchanged,
releasetheinfobutton.
Wait30secondsforthedisplaytoshowtemperature.
Seeimage4.
HOW TO CHANGE “DEFROST
INTERVALS”
May need to unlock control.
This can only be changed if defrost mode parameter “DFM” is set for “TIM”.