Use and Care

............ www.truemfg.com ............
True Food Service Equipment, Inc.
16
16
Follow these instructions at ALL times when you
replace a CO
2
gas cylinder:
1. Closecylinderat"A".
2. Removetap"D"frombarrel.Pullpressurerelease
ringonbodyoftaptoreleasepressureremainingin
line.(donotclose"C")
3. Removeorloosenregulatorkey"B"byturning
counterclockwise.
4. Removeregulatorfromusedcylinderat"E".
5. Removedustcapfromnewgascylinderat"E"and
cleardustfromoutletbyopeningandclosingvalve
"A"quicklyusingappropriatewrench.
6. Attachregulatortonewcylinderat"E".(usenew
fiber/plasticwasher,ifrequired).
7. Openvalve"A"alltheway.
8. Closevalve"C".
9. Adjustregulatorkey"B"byturningclockwisetoset
pressure.(checksettingbyopening"C"andpulling
andreleasingthering"F"onthepressurerelease
valveonthebodyofthetap)
10. Tapbarrelat"D"withvalve"C"open.
NOTE
Don't lay CO
2
cylinders flat.
Don't drop CO
2
cylinders.
It requires 1/2 pound CO
2
to dispense 1/2 barrel of beer
at 38˚F with 15 pounds pressure on barrel.
PRESSURE ADJUSTMENT ON CO
2
REGULATOR
Increasing Pressure:
1. Closeregulatorshut-off"C".
2. Turnregulatorkey"B"clockwiseandmakesetting.
3. Tapgaugeforaccuratereading.
4. Openregulatorshut-off"C"anddrawbeer.
Decreasing Pressure:
1. Closeregulatorshut-off"C".
2. Untapbarrelat"D"andtobleedline,activatetap
handle.Leaveinopenposition.
3. Slowlyopenregulatorshut-off"C"and
simultaneouslyturnregulatorkeycounter-clockwise
tozeroreading.
4. Closeregulatorshut-off"C"andsetpressureby
turningregulatorkeyclockwise.Checksettingby
openingandclosingvalve"C".
5. Closetaphead"D".(putin"OFF"position)
6. Tapbarrelat"D"andopenregulatorshut-off"C".
CHANGING CO
2
GAS CYLINDER
A
B
C
D
E
F
MAINTENANCE, CARE & CLEANING