Use and Care

............ www.truemfg.com ............
10
10
True Food Service Equipment, Inc.
INSTALL DRAFT ARM continued...
Insertairhose(oneinchplastictube)
indraftarm,beingcarefulnottodisturb
insulation.Removetopcoverofdraftarm
andattachairhosecliptotheinsulating
sleeveatthetopofthedraftarm.Replace
topcover.Theairhoseclipwillassurethat
thehoseremains
inproperplaceatalltimes,keeping
thebeerfaucetcold.(Seeimage7-9)
............ www.truemfg.com ............
INSTALLATION / OPERATION INSTRUCTIONS
DIRECT DRAW DRAFT ARM INSTALLATION
CONTINUED...
A. Thecompressorisreadytooperate.Pluginthe
cooler.
B. TemperaturecontrolsetatNo.4positiongives
refrigeratorsanapproximatetemperatureof35°Fand
glasschillerfrostershaveanapproximatetemperatureof
0°F.Allowunittofunctionseveralhours,completely
coolingcabinetbeforechangingthecontrolsetting.
C. Excessivetamperingwiththecontrolcouldleadto
servicedifficulties.Shoulditeverbecomenecessary
toreplacetemperaturecontrol,besureitisordered
fromyourTRUEdealerorrecommendedservice
agent.
D. GoodairflowinyourTRUEunitiscritical.Be
carefultoloadproductsothatitneitherpresses
againstthebackwall,norcomeswithinfourinchesof
theevaporatorhousing.Refrigeratedairoffthecoil
mustcirculatedownthebackwall.
LIGHT SWITCH LOCATION:
Theswitchislocatedonthefrontoftheevaporator
housingtowardthefrontofthecabinet.Openthefront
doorsandtheswitchwillbevisibleclosetotheceiling
thecabinet.
NOTE
If the unit is disconnected or shut off, wait five minutes
before starting again.
RECOMMENDATION
Before loading product we recommend you run your TRUE
unit empty for two to three days. This allows you to be sure
electrical wiring and installation are correct and no shipping
damage has occurred. Remember, our factory warranty does
not cover product loss!
REPLACEMENT PARTS
TRUE maintains a record of the cabinet serial number for
your cooler. If at any time during the life of your cooler, a
part is needed, you may obtain this part by furnishing the
model number and serial number to the company from whom
you purchased the cooler. Call Toll-Free: (800)-424-TRUE
(Direct to Parts Department). (800)-325-6152 (U.S.A.
& Canada only) or call: (636)-240-2400.
STARTUP