Spec Series Manual
14
Info/Set Point
Button
Manual Defrost/
Down Button
Manual Activation/ 
Up Button
Stand-By
Button
Compressor
Running
Activation of 2nd 
Parameter Set - NA
Alarm - NA
Cabinet in Defrost
Evaporator Fan 
Running
LAE Control Icons
LAE Electronic Control
HOW TO INITIATE A MANUAL DEFROST
May need to unlock control.
WHY:
A ONE TIME ADDITIONAL DEFROST MAY BE NECESSARY 
TO CLEAR ACCUMULATED FROST/ICE FROM EVAPORATOR 
COIL.
HOW:
The method to initiate a manual defrost is determined by 
the Defrost Mode Parameter “DTM” preprogrammed in 
the controller.
A.  REGULAR TIME DEFROST (TIM)
  If controller is preprogrammed for “TIM”, press and 
release the Manual Defrost button until “dEF” appears.
B.  REAL TIME CLOCK (RTC)
  If controller is preprogrammed for “RTC” press the and 
hold the Manual Defrost button for 5 seconds until 
“dh1” appears. Release the Manual Defrost button 
and then press and hold for an additional 5 seconds 
until “dEF” appears.
DEFROST WILL ONLY TERMINATE ONCE A SPECIFIC PRESET 
TEMPERATURE OR A PRESET TIME DURATION IS REACHED.