Spec Series Manual
19
STR•STA
•STG
DOOR OPERATION
Door Configuration:
After installing, cabinet doors can be 
adjusted for alignment. The hinge on 
the door and hinge on the cabinet can 
be adjusted accordingly. 
Step 1
To remove door open at a 90˚ angle 
from the cabinet and lift door up and 
out from the cabinet hinges carefully 
avoiding rainshield. Rest the door in a 
safe area. 
Step 2
Remove gray plastic cover from hinge 
located on the cabinet. (See image 1). 
Use a standard screw driver and pry out 
the gray cover. This exposes the three 
Phillips screw anchoring the hinge to 
the cabinet. (See image 2). Loosen 
these three screws but don’t remove 
them. Adjustment can be made slightly 
up/down and side to side. 
Step 3
The hinge on the cabinet door can also 
be adjusted. Remove cover from hinge 
located on the door. Pull on the cover 
directly out from the door. (See image 
3). This exposes the three Phillips 
screws anchoring the hinge to the door.  
Loosen these three screws but don’t 
remove them. The hinge can be 
moved side to side, up and down. (See 
image 4).
NOTE:
When tightening the hinges to 
the cabinet and door do not 
apply pressure to the Phillips 
screws. Carefully anchor them 
without applying extreme 
amounts of pressure.
Step 4
To adjust the lock latch remove two 
Phillips screws and the latch can be put 
to the side for later reinstallation. (See 
image 5). The lock base that anchors 
the latch can be adjusted simply by 
loosening the two Phillips screws, but 
not removing them. Then the lock base 
can be moved side to side for 
adjustment. (See image 6). After 
adjustment is complete tighten the lock 
base and install the latch back into 
place.