Use and Care

16
True
glass door merchandisers
www
.truemfg.com
INSTAllATION INSTRUCTIONS
TEMpERATURE CONTROl AlTITUdE AdJUSTMENT:
REqUIREd TOOlS:
• AllenWrench(5/64”)
• TorxScrew(T-7)
The scale to the right may be used as a guide for measuring degrees of rotation required for altitude
correction. The arrows indicate direction of screw rotation. See Figure 1.
IMpORTANT:UprightmodelsorderedwithHighAltitude”temperaturecontrolsare
pre-calibrated and do not require adjustment.
90
180
270
360
1
Scale Guide for Measuring
INSTRUCTIONS: dANfOSS TEMpERATURE CONTROl AdJUSTMENT fOR
HIGH AlTITUdE ApplICATIONS
STEp 1 - Unplug cooler.
STEp 2 - Remove the screws that secure the temperature control to the inset box.
STEp 3 - To make these adjustments it may be necessary to remove the temperature control from the housing.
NOTE: You may have to remove the wires attached to the control. Take note as to which wire is on which spade terminal.
STEp 4 - Pull out gently from cabinet.
NOTE: Mechanical temperature controllers are affected when functioning at high altitude.
The cut-in and cut-out temperatures will be colder than when the controller functions closer to sea level.
STEp 5-Forhighelevationinstallations,itmaybenecessaryto“warm-up”thesetpoints.Tomaketheadjustment,insertthe
appropriate tool in each adjustment screw and turn 1/4 of a revolution clockwise (to the right). This procedure will adjust both
the cut-in and cut-out about 2˚F warmer.
STEp 6 - Make sure to reconnect the wires to the proper spade terminal when reinstalling.
INSTRUCTIONS: CUTlER HAMMER TEMpERATURE CONTROl AlTITUdE AdJUSTMENT
STEp 1 - Unplug cooler.
STEp 2-Turnthetemperaturecontroltothe“9”position.
STEp 3 - Remove the screws that secure the mounting plate to the evaporator top. See Figure 2.
STEp 4 - Pull control down gently from housing.
STEp 5 - Turn screws counterclockwise (CCW).
STEp 6-Reassembletocoolerhousingandreturnthetemperaturecontroltothe“5”position.