ELECTRICAL SPECIFICATIONS
Do not, under any circumstances, cut or remove 
the third (ground) prong from the power cord. For 
personal safety, this appliance must be properly 
grounded.
To minimize the depth of the cutout opening, the 
electrical outlet must be positioned as shown below. 
Outlet must be flush with wall. 
Before your new unit is connected to a power supply, 
check the incoming voltage with a volt meter. If 
anything less than 100% of the rated voltage for 
operation is noted, correct immediately.
The power cord of this appliance is equipped with 
a 3-prong (grounding) plug which mates with a 
standard 3-prong (grounding) wall outlet to minimize 
the possibility of electric shock hazard from this 
appliance. A 115V AC, 60 Hz, 15 amp circuit 
breaker and electrical supply are required.  
Each unit requires a dedicated circuit. Have the wall 
outlet and circuit checked by a qualified electrician 
to make sure the outlet is properly grounded.
If the outlet is a standard 2-prong outlet, it is your 
personal responsibility and obligation to have it 
replaced with the properly grounded 3 prong wall 
outlet.
Do not use an extension cord or two prong adaptor.  
Electrical ground is required on this appliance.
The unit should always be plugged into its own 
individual electrical circuit, which has a voltage rating 
that matches the rating plate. This provides the best 
performance and also prevents overloading house 
wiring circuits which could cause a fire hazard from 
overheated wires. Never unplug your refrigerator by 
pulling on the power cord. Always grip plug firmly 
and pull straight out from the outlet.
Repair or replace immediately all power cords that 
have become frayed or otherwise damaged. Do not 
use a cord that shows cracks or abrasion damage 
along its length or at either end. When moving the 
refrigerator away from the wall, be careful not to roll 
over or damage the power cord.
OUTDOOR USE
All True undercounter units are UL-rated for outdoor 
use.
In regions that have high dewpoint/high humidity, it 
is possible that you will see some condensation on 
the glass and possibly around some of the gasket 
seals. For best operation, it is recommended that 
your True unit be stocked full with product.
To winterize your True unit, it is recommended once 
the temperature reaches below 32ºF consistently that 
products are removed from the unit, the unit is either 
unplugged or turned OFF, and a cover is placed over 
the unit.
Installation – For best operation, it is recommended 
that your True unit is installed so that the countertop 
of your outdoor kitchen/bar covers the door or drawer 
gasket. Cutout opening should be a minimum of 24 
inches deep and unit should be installed “flush”.  
Please note that door/drawer gaskets do not provide 
a water tight seal against the elements. 
2" 2"
8"
Rear wall of cut out