TUI15 Installation Guide

36
TRUE RESIDENTIAL LINE
SANITIZING
1. Mix 1.5 fluid ounces (3 tablespoons) of 5.25%
hypochlorite solution (chlorine bleach) with 3
gallons of warm water.
2. Use 1/2 of the solution to sanitize the removed
parts. Soak the parts in the solution. Do not
rinse the parts after sanitizing.
3. Use the remaining solution to sanitize the
interior surfaces of the machine and the bin.
Do not rinse the sanitized areas.
4. Replace all components.
5. Press and hold the
CLEAN
button for
three seconds.
6. When the machine says “Add, pour 2 teaspoons
of 5.25% hypochlorite solution (chlorine bleach)
into the spray compartment.
7. When the cleaning cycle is complete, the
machine will resume its previous mode
(either OFF or ICE).
8. Immediately rinse off and dry any exterior areas
where sanitizing solution may have spilled.
EXTERIOR CLEAN
Wipe with a damp cloth to remove dust and dirt. Use
a solution of mild dish soap and water if a greasy
residue persists. Wipe dry with a clean,
soft cloth. Never use abrasives, chlorinated or
citrus-based cleaners on exterior panels.
WINTERIZING INSTRUCTIONS
Use the following instructions to prepare your ice
machine for storage or winterization:
1. Descale and sanitize the ice making system per
the instructions on page 39.
2. Turn off the water supply.
3. Disconnect the incoming water line from
the back of the unit.
4. Remove the water filter by twisting it counter
clockwise and pulling it out of the unit.
5. Drain the evaporator compartment by removing
the pump clean-out cap per the instructions on
page 31.
6. Switch off and unplug the ice machine.
7. Pour 1 gallon of propylene glycol
(RV antifreeze) into the bin drain to
fill the drain pump.
RESTART INSTRUCTIONS
Use the following instructions to restart your ice
machine after winterization:
1. Install a new water filter in the unit.
2. Reconnect the incoming water line
and turn on the water supply.
3. Plug in the unit.
4. Descale the ice machine per the instructions on
page 35.
5. Press the power button to start ice making.
NOTE: THE FRESH WATER THAT IS INTRODUCED
DURING DESCALING AND START-UP WILL FLUSH
THE PROPYLENE GLYCOL DOWN THE DRAIN.