Installation Sheet
6
TRUE RESIDENTIAL
®
ELECTRICAL REQUIREMENTS
For all built-in models, the electrical supply should be located within the shaded area shown in
the illustration. Follow the National Electrical Code and local codes and ordinances when installing
the receptacle. A separate circuit, servicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause interruption of operation.
NOTES:
• THE OUTLET MUST BE CHECKED BY A QUALIFIED ELECTRICIAN TO BE
SURE THAT IT IS WIRED WITH THE CORRECT POLARITY.
• VERIFY THAT THE OUTLET IS PROPERLY GROUNDED.
• POWER SUPPLY 115 V AC, 60 HZ
• CIRCUIT BREAKER 15 AMP
• RECEPTACLE 3-PRONG GROUNDING-TYPE