Instructions / Assembly

FOR YOUR SAFETY
WARNING: BE SURE THE ELECTRICITY TO THE WIRES YOU ARE
WORKING ON IS SHUT OFF; EITHER THE FUSE IS REMOVED OR THE
CIRCUIT BREAKER IS SHUT OFF.
GENERAL
You don’t need special tools to install this fixture. Be sure to follow the steps
in the order given. Under no circumstances should a fixture be hung on house
electrical wires, nor should a swag type fixture be installed on a ceiling which
contains a radiant type heating system. Read instructions carefully. If you are
unclear as to how to proceed, consult a qualified electrician.
NOTE: Proper wiring is essential for the safe operation of this fixture.
Carefully remove the fixture from the carton and check that all parts are
included as shown in figure. Be careful not to misplace any of the screws
or parts, which are needed to install this fixture.
IMPORTANT:Do not attach fixture directly to outlet box.
STEP 1 Thread the mounting screw (A) into the matching holes in the
circular strap (B).
STEP 2: Secure the circular strap (B) to outlet box with the outlet box
screws (C).
FIXTURE ASSEMBLY
INSTALLATION
STEP 2: Take note of the color of the wire(s) on your fixture. Identify which
group your fixture wire(s) falls into and connect the wires according to the
directions below:
GROUNDING INSTRUCTIONS
STEP 1: Insert the green grounding screw into the hole with two raised
dimples on the mounting bar. Wrap the ground wire from the fixture
(if supplied) around the green grounding screw, then connect it to ground
wire from the outlet box (if not fixed on the outlet box) using a wire connector
(not supplied). If ground wire from the fixture is not supplied, wrap the ground
wire (if not fixed on the outlet box) from the outlet box around the green
grounding screw and tighten it.
NEVER CONNECT GROUND WIRE TO BLACK OR WHITE POWER
SUPPLY WIRES.
GROUP A:
Connect to Black House Wire
GROUP B:
Connect to White House Wire
BLACK WHITE
*PARALLEL WIRE (round & smooth) *PARALLEL WIRE (square & ridged)
WHITE OR GREY WITH TRACER WHITE OR GREY WITHOUT TRACER
BROWN, GOLD OR BLACK
WITHOUT TRACER
BROWN, GOLD OR BLACK
WITH TRACER
NOTE:When parallel wire (SPT-I & SPT-2) is used, the tracer wire is square
shaped or ridged and the less tracer wire is round in shape or smooth (seen
best when viewed from wire end.)
STEP 3: Take your fixture wire(s) from group A and place evenly against the
black wire from the outlet box. Do NOT twist wires together before using wire
connectors.
STEP 4:Fit a wire connector over the wires and screw the connector
clockwise until you feel firmness.
STEP 5: Try gently to pull the connector off the wires. If you can pull the
connector off, carefully re-do steps 3 and 4 as above, and check again for
a firm connection.
STEP 6: Connect the fixture wire from group B to the white wire from the
outlet box in the same manner. Make sure no bare wires can be seen
outside wire connectors.
FINAL ASSEMBLY
STEP 1: After wires are connected, tuck them carefully inside outlet box.
Raise canopy (D) allowing the mounting screw (A) to protrude through the
hole in the canopy (D), and secure with finials (E).
STEP 2: Install lamps (F) (not supplied). Do not exceed the maximum
capacity recommended on the socket.
CLEANING
To clean, wipe fixture with a soft cloth. Clean glass with a mild soap. Do not
use abrasive materials such as scouring pads or powders, steel wool or
abrasive paper.
ORDERING PARTS
Keep this sheet for future reference, and in case you need to order replacement
parts. Be sure to use exact wording from illustration when ordering parts.
INSTALLATION AND SAFETY INSTRUCTIONS
Line art shown may not exactly match the fixture enclosed. However, the installations
do apply to this fixture.
FIGURE
A
B
C
D E
F
CONTACT US
E-mail:service@24h-reply.com

Summary of content (1 pages)