Data Sheet
POWER - NIKKOHM
50W TO263 (D2PAK) HIGH POWER RESISTORS
TCP50E
Specifications
Rated Power 50 Watt -55 °C to 25 °C flange temperature
Rating Power 1 Watt Free air.
Heat Resistance 2.3 °C/W Hot spot to flange
Resistance Range 0.02-0.091 Ohm 0.1-510 k Ohm 10-51K Ohm
Nominal Resistance E6 E24+ E24 Include 2.5, 4.0, 5.0, 8.0 and 16
TCR (ppm/deg C) 250(H) 100 (A) 50 (C) -55 °C to +155 °C
Tolerance 5%(J) 1% (F), 5% (J) +/-1% (F) Note 2
Resistor Material Thick Film Thin Film
Capacitance 1.69pF Equivalent parallel capacitance.
Inductance 9.65nH Equivalent series inductance
Operation Temp. Range -55°C to +175 °C
Max. Operating Volt. Small value either 700V or
RP
P is rating power and R resistance
Withstanding Voltage 2000 VAC 60 seconds. 1mA
Load Life +/- 1.0 % 25 °C, 90 min. ON, 30 min .OFF, 1000 h.
Humidity +/- 1.0 % 40 °C, 90-95%RH, DC 0.1W, 1000 h.
Temp. Cycle +/- 0.25 % -55 °C,30min.,+155°C,30min., 5cycles
Soldering Heat +/- 0.1 % 350+/-5 °C, 3seconds,
Solder ability Over 95% of surface 230+/-5 °C, 3seconds.
Insulation Resistance Over 1,000 Meg Ω Between terminals and flange.
Vibration +/- 0.25 % IEC60068-2-6, see note 4
Flammability UL94V-0
Weight 1.5 grams
Derating Temperature Rise
Frequency Characteristics
RoH
S
Nikkohm Co., Ltd. 3-31-2640 Minamicho, Misawa, Aomori 033-0036 Japan TEL: +81-176-53-2105, FAX: +81-176-53-2106
© Nikkohm Co., Ltd. All rights reserved. URL: http://www.nikkohm.co.jp & http://www.nikkohm.com / e-mail: info@nikkohm.com
Temperature Rise (°C)
140
TCP50EC500 F
120
100
Resistor
temperature on resistor based
80 referenced from flange temperature
.
60
40
20
0
0 10 20 30 40 50
Power (Watt)
Impedance (Ω)
10K
TCP50E C10K0F
TCP50E C1K0F
1K0
TCP50E C101F
100
TCP50E C500F
TCP50E C220F
10
100k 1M 10M 100M 1G 10G
Frequency (Hz)
Note:
(1) Resistance measurement shall be made at a point 5.27mm +/-0.6 mm from the resistor body.
(2) TCR of low resistance will be increased as 300ppm/0.02Ω, 200ppm/0.05Ω, 140ppm/0.1Ω and 80ppm/0.2Ω typically. Testing point is at 5.27mm from bottom
of molding of terminals.
(3) Test method is IEC60068-2-6, and specification is sine sweep wave form, 100Hz-2000Hz, 10 cycles, amplitude 0.75mm or 100m/s
2
, 90minutes. direction x-y z,
Amplitude 0.75mm will be applied under break point Frequency (about 60Hz) and 100m/ s
2
over break point
(6) Standard packaging is anti-static PE tape and reel, reel contains 500pcs/reel.
Pu
l
se Dura
b
i
l
ity
10n 100n 1u 10u 100u 1m 10m 100m 1 10 100
Pulse Width(seconds)
100k
10k
1k
100
10
Pulse Peak Power(W)
TCP50E C100F
400W
50W
Tentative continuous-pulse power allowance at duty 0.01.
Load life test will be necessary in actual equipment,
Because curve will be changed by resistance, repetition,
dut
y
and o
p
eratin
g
tem
p
erature.
Rating Power (W)
+25°C
50
40
30
20
10
0
-50 0 50 100 150 200
Flange Temperature (°C)
+25°C
+175°C
Conrad Electronic SE - Klaus-Conrad-Str.1 - 92250 Hirschau - www.conrad.de