Datasheet
Distributed by Conrad Electronic SE • Klaus-Conrad-Str. 1 • D-92240 Hirschau
Datasheet
Item no. 1497956
V1_09262017_01_en
3
This is a publication by Conrad Electronic SE, Klaus
-
Conrad
-
Str. 1, D
-
92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction
by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require t
he prior written approval by
Insertion: 35N max. at a max. rate of 12.5 mm per minute.
Withdrawal: 10N min. at a max. rate of 12.5 mm per minute.
Durability: 1,500 cycles insertion/ extraction cycles at a max. rate of
200 cycles per hour
Cable Pull-Out: After the application of a stead y state axial load of 40N for one min.
Cable Flexing: A traverse 180º in one direction plus 180º in the opposite direction shall
be called one cycle, the cycling rate shall be 12 to 14 cycles per min.
After completion of 100 cycles, test withstanding voltage and insulation
resistance.
Physical Shock: No discontinuities of 1µs or longer duration when mated USB connectors
are subjected to 11 ms duration 30 Gs half-sine shock pulses. Three
shocks in each direction applied along three mutually perpendicular
planes for a total of 18 shocks.
Random Vibration: The electrical load conditions shall be 100mA max. for all contacts.
Frequency: 50 to 2000 Hz
PDS: 0.04 g² / Hz
Duration: 1 Hour/ Axis, 3 Axis total
G’s: 7.56 g rms
Thermal Shock: 5 cycles at -40°C / +105°C, after the test, the function and appearance
can’t be impacted.
Humidity Life: 96 hours min. (seven step cycles)
Salt Spray: The test liquid (Nacl) thickness is 5%, Compressing the air pressure is
0.083 Mpa, Spraying amount is 1~2 ml/80cm/h, Temperature of the pressure
barrel is 43°C, LAB temperature is 35°C, relative humidity of LAB is 95%~98%,