Datasheet

Page 7 of 7 QR-QE-20/2003.08.01
6
Contact
resistance
接觸阻抗
Less than 100 mΩ
低於 100 mΩ
Apply 2 times of the operating force of the
static load on the vertical direction of the
lever, measure the resistance by using the
Contact Resistance Tester with 1KHZ,
20mV, 5~50mA of current.
將兩倍於作動力之靜負荷加於操作柄之
中央以(1KHZ,20mV, 5~50mA)微電流接觸
阻抗計測定.
7
Insulation
resistance
絕緣阻抗
More than 100 MΩ
100 MΩ以上
A voltage of DC100V is applied between
terminals.
DC100V
之電壓加於端子間測定
.
8
Withstand
voltage
耐電壓
There shall be no damage, arc or
dielectric breakdown.
無絕緣破壞之現象
A voltage of AC 250V(50~60HZ) shall be
applied for 1 min between terminals.
AC250V(50~60HZ)電壓施加於端子間1
分鐘.
9
Rated power
額定功率
12 V DC 50 mA
Within 70
小於 70
10
Number of
cycles
開關耐久次數
Contact resistance 200mΩ Max,
No mechanical malfunction.
接觸阻抗最大 200mΩ,
機械方面能動作.
100,000 Cycles min
Other / Cycles min
五、General 一般事項
NO.
ITEM
Unless otherwise specified, test and measurement should be carried out in following condition:
如無特殊要求,試驗與測試將按以下條件進行:
Ambient temperature
溫度
15°C to 35°C
Relative humidity
相對濕度
25% to 75%
1
Air pressure
氣壓
86 KPa to 106 KPa
2
Operating temperature range
使用溫度範圍
-10°C to +70°C
3
Storage temperature range
儲存溫度範圍
-30°C to +80°C
Approved
核 准
Q.I.Department
審 查
Design dept.
經 辦 者