Datasheet

Page 4 of 7 QR-QE-20/2003.08.01
3
Pull strength
of lever
搖杆拉拔強度
More than 5.0 Kgf
3 seconds min
大於 5.0Kgf,至少 3 秒鐘
Apply specified pull force on the lever
upward.
作用於搖杆上,沿搖杆方向向上.
4
Push
Strength of
lever
搖杆推強度
More than 3.0 Kgf
3 seconds min
大於 3.0Kgf,至少 3 秒鐘
Apply specified push force on the lever
downward.
作用於搖杆上,沿搖杆方向向下.
5
Operating
force of
lever
搖杆作用力
160±40 gf
□220±40 gf
Test position More than 10 degrees
deflection of lever.
搖杆偏斜 10 度以上之位置測定.
6
Accuracy of
reset
position of
lever
搖杆復歸精度
±5°
Measure the angle between the lever and
the axial center line after the lever
pushed to the direction of X-X(Y-Y) and
resets.
搖杆推向 X-X(Y-Y)方向自由復歸後測搖
杆與垂直中心線的角度.
7
Operation
angle of
lever
搖杆使用有效
角度
Refer to attached product
drawing
見成品圖
The maximum angle of the lever pushed
to the direction of X-X and Y-Y and
45°.
搖杆推向 X-X(Y-Y) 45°方向的最大角
度.
. ENDURANCE CHARACTERISTICS 耐久性能(Single test of item 單一測試項目)
序號
NO.
ITEM
PERFORMANCE
測試條件
TEST CONDITIONS
1
Free falling
自由落下試驗
No damage and lever
deformation, but deformations
of terminals and molded parts
are allowed.
無不良產生,端子變形除外.
Height: 75cm
Number of falls: 3 times
從高度為 75 釐米落下測試 3 次後
2
Dry heat
耐熱性
Variation of total resistance
should be within
+5%
30%.
To be operated mechanically.
全阻值變化要在
+5%
30%以內,
機械方面能動作。
Temperature:+80 ±2
Time: 96 hours
The controller shall be subjected to standard
atmospheric conditions for 2 hours after which
measurement shall be made.
溫度在80±2 放置96小時.2小時后正常狀
態下測試.