Datasheet
Distributed by Conrad Electronic SE • Klaus-Conrad-Str. 1 • D-92240 Hirschau 
Datasheet 
Item no. TC-TS30-10N-1,2, TC-TS30-10P-1,2 
 TC-TS30-15N-1, 2, TC-TS30-15P-1,2 
V1_09062017_01_en
1 
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require the prior 
written approval by the editor. Reprinting, also in part, is prohibited. This publication represents the technical status at the time of printing.
© Copyright 2017 by Conrad Electronic SE. 
Specifications 
Item       Standard 
Differential travel       10% max. of sensing distance 
Target      Ferrous metal (The sensing distance decreases with non-ferrous metal.) 
Power supply voltage      12 ~ 24 VDC. Ripple (p-p) : 10% max. 
(operating voltage range)     (10 ~ 30 VDC) 
Current consumption (DC 3-wire)    10 mA max. 
Output type      See product selection 
Control load current output (See note 1.)    200 mA max. (32 Vdc max.) 
Residual voltage      1 V max. (under load current of 200 mA with cable length of 2 m) 
Operation mode      See product selection 
(with sensing object approaching) 
Protection circuit      Output reverse polarity protection, power source circuit reverse 
          polarity protection, 
          Surge suppressor, Short-circuit protection 
Ambient air temperature    Operating: -40°C to 70°C, Storage: -40°C to 80°C( with no icing or condensation) 
Temperature influence (See note 1.)    ±10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C 
           ±15% max. of sensing distance at 23°C within temperature range of -40°C to 70°C 
Ambient humidity      Operating : 35% to 95%, Storage : 35% to 95%   
Voltage influence      ±1% max. of sensing distance in rated voltage range ±15% 
Insulation resistance      50MΩ min. (at 500 VDC) between current carry parts and case   
Dielectric strength      1,000 VAC at 50/60 Hz for 1 min between current carry parts and case 
Vibration resistance      10 to 55 Hz, 1.5mm double amplitude for 2 hours each in X, Y and Z directions 
Shock resistance      1,000 m/s2, 10 times each in x, Y and Z directions 
Note 1. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 
 30 and 32 VDC, use a load current of 100 mA max., 