Certificate

Note 4D - UL61058-1 - Heating test was conducted at ambient temperature of 85 degC with measured maximum temperature of 92.6 degC on
terminals, the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
Note 5 - These switches have a contact gap exceeding 3mm.
Note 5A - UL61058-1 - The Switch body is installed inside of end product; only consider the Rocker as accessible parts.
Note 6 - These switches may be provided with a light. Lamp life has not been evaluated.
Note 6A - UL61058-1 - The terminals have been evaluated for use with 2.5 mm2 flexible stranded and 4.0 mm2 rigid conductors.
Note 6B - UL61058-1 - The Switch body is installed inside of end product; only consider the Rocker as accessible parts.
Note 6C - UL61058-1 - Heating test was conducted at ambient temperature of 85 degC with measured maximum temperature of 104.6 degC on
terminals, the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
Note 7A - UL61058-1 - The terminals have been evaluated for use with 1.5 mm2 flexible stranded and 2.5 mm2 rigid conductors.
Note 7B - UL61058-1 - The Switch body is installed inside of end product; only consider the Toggle as accessible parts.
Note 7C - UL61058-1 - Heating test was conducted at ambient temperature of 85 deg C with measured maximum temperature of 100.4 deg C on
terminals, the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
Note 7D - These switches, Models R13-447 and R13-448 Series, were investigated for the IP56 rating when mounted in a representative end-
product enclosure as defined by the manufacturer. The suitability of the protection from solid objects or water for parts enclosed in the end product
shall be considered in the end-use investigation.
Note 8 - These switches shall be mounted on or supported by a plastic material enclosure suitable for direct support of live parts.
Note 8A - UL61058-1 - The Switch body is installed inside of end product; only consider the Rocker as accessible parts.
Note 8B - UL61058-1 - Heating test was conducted at ambient temperature of 85 degC with measured maximum temperature of 125.4 degC on
terminals, the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
Note 8C - UL61058-1 - IP 40 for accessible parts and enclosure of the end product enclosure when mounted or installed according to the
manufacturers directions. Internal parts were not evaluated for IP ratings and must be considered in the end product.
Note 9 - These switches employ a lamp that is powered by a separate DC source. Lamp DC source should be evaluated for compliance with the
end-use standard.
Note A1 - The switch having three poles connected Test Circuit B and Test Circuit A was subjected to the subject evaluation.
Note A4 - The Printed Wiring Board assembly has not been evaluated, the acceptability for use with end-product and spacings shall be determined
in the end-product application.
Note A5 - The Linking Sheet has not been evaluated, the acceptability for use with end-product and spacings shall be determined in the end-
product application.
Notes 12A - When mounted in accordance with the manufactures instruction, this switch gets a protection degree of IP 40.
Notes 12B - The Switch body is installed inside of end product; only consider the Actuator as accessible parts.
Notes 12C - Heating test was conducted at ambient temperature of 85 deg C with measured maximum temperature of 87.8 deg C on terminals, the
suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
Notes 13A - When mounted in accordance with the manufactures instruction, this switch gets a protection degree of IP 40.
Notes 13B - The Switch body is installed inside of end product; only consider the Actuator as accessible parts.
Notes 13C - Heating test was conducted at ambient temperature of 85 deg C with measured maximum temperature of 100.8 deg C on terminals,
the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
^Note 1 - UL61058-1 - These are lighted switches employing a lamp. The usable lamp life has not been evaluated.
^Note 2 - UL61058-1 - The device is factory wiring with terminals that do not allow the wire to be removed once inserted.
^Note 3 - UL61058-1 - Only the Button is considered as accessible parts to users. For rest parts of the switches that shall be enclosed with a
suitable enclosure, and the acceptability shall be determined in end-product applications.
^Note 4 - UL61058-1 - The solder type terminal has evaluated the solderability of 260 degree of C.
Marking: Company name or tradename "SCI" or trademark
, , , catalog, model or part number, electrical
ratings and the Recognized Component Mark,
on the product or on the smallest unit container in which the product is packaged.
Last Updated on 2018-06-14
Questions? Print this page Terms of Use Page Top
© 2018 UL LLC
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading
manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission
from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following