Certifications
R13-87H, R13-
87I
16 125 60 1/3hp 6K 85 2/M -/- 2, Note 5
10 250 60 1/2hp 6K
R13-901 6 125 60 GP 6K 55 1/1 -/- -
3 250 60 GP 6K
R13-915, R13-
915B2
5 125 60 GP 6K 65 1/1 -/- -
- 250 60 1/4hp 6K
R13-918B-02 16 125 60 GP 6K 105 1/1 -/A -
10 250 60 GP 6K
- 125 60 1/3hp 6K
- 250 60 1/2hp 6K
R14-6S, R14-6Q w/ wo 1 or 2
5 125 60 GP 6K 65 1/1 -/- Note 1, 2, 3
3 250 60 GP 6K
16A - IP65 and IP40 - for accessible parts and enclosure of the end product enclosure when mounted or installed according to
the manufacturers directions. Internal parts were not evaluated for IP ratings and must be considered in the end product.
16B - The Switch body is installed inside of end product; only consider the Actuator as accessible parts.
16C - Heating test was conducted at ambient temperature of 85 deg C with measured maximum temperature of 119.7 deg C
on terminals, the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
20A - IP 4X testing was completed on the complete switch without an end product enclosure. The switch gasket (seal) to the
end product enclosure is evaluated in the end product testing.
22A - IP 40 testing was completed on the complete switch without an end product enclosure. The Inner Boot must be provided
to maintain the IP40 function. The switch gasket (seal) to the end product enclosure is evaluated in the end product testing.
22B - During the wiring installation for M4 Screw, the switch terminals need to fix by jig or tool before screw tightly.
9A - The lighted switches rated DC rating only employing DC lamps; the lighted switches rated AC rating only employing AC
lamps.
9B - The Switch body is installed inside of end product; only consider the Actuator as accessible parts.
9C - Heating test was conducted at ambient temperature of 85 deg C with measured maximum temperature of 108.8 deg C on
terminals, the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
9D - After 6K Endurance cycles, the switches rated 20RA, 125 V ac were evaluated for temperature test at 18 A only.
9E - The switches get a protection degree of IP 66 in accordance with the manufacturer's mounting means only. For IP 6X dust
test, talcum powder did enter the mounting enclosure and deposited on terminals of the switch but the talcum powder did not
enter the switch housing. The suitability of mounting means for the switches shall be determined in end-product applications.
A2 - The construction applied for the rating 16 A and 14 A is different. The spring with 12.5 mm long is used for 14/10 A,
125/250 V ac; 1/3 hp, 125 V ac; 1/2 hp, 250 V ac. The spring with 13.3 mm long is used for 16/10 A, 125/250 V ac; 1/3 hp, 125 V
ac; 1/2 hp, 250 V ac.
A3 - Waterproof should be evaluated for compliance with the end-use product Standard.
Note 1 - The switch terminals have not been investigated for printed circuit board connections. The suitability of these
Page 3
9
of 4