Datasheet

Absolute Maximum Rating (Ta=25ɗ)
Parameter Symbol Absolute Maximum Rating Unit
Forward Pulse Current I
FPM
100 mA
Forward Current I
FM
30 mA
Reverse Voltage V
R
5 V
Power Dissipation P
D
150 mW
Operating Temperature Topr -40̚+80 ć
Storage Temperature Tstg -40̚+100 ć
Soldering Heat (5s) Tsol 260 ć
Electro-Optical Characteristics (T
a
=25ɗ)
Parameter SymbolMin. Typ. Max. Unit Test Condition
Luminous Intensity Iv --- 15000 20000mcd IF=20mA(Note1)
Viewing Angle
1/2
--- 15 --- Deg (Note 2)
Peak Emission Wavelength λp 585 --- 595 nm IF=20mA
Spectral Line Half-Width Ƹλ 15 20 25 nm IF=20mA
Forward Voltage V
F
1.9 --- 2.5 V IF=20mA
Reverse Current I
R
--- --- 10 µA VR=5V
Note:
1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
eye-response curve.
2.
θ
1/2