4. For a variable negative power supply:
- Connect a suitable cable to the screwed connection 0~ -15V (6). Connect the other end
of the cable to the desired negative plug array (-).
- Connect a suitable cable to the ground connection (3). Connect the other end of the cable
to the corresponding positive plug array (+).
- The voltage can thus be set with the rotary switch V- (7). Measure the voltage level with
a suitable measuring instrument to determine the required voltage.
5. Set up your circuit.
6. Switch the power supply on with the on/off switch (1).
If the circuit doesn’t function, immediately switch the device off with the on/off switch
and correct the set-up.
Replacing the fuse
1. The fuse compartment is located on the back of the breadboard, next to the power cord
terminal.
2. Use a Phillips screwdriver to open the fuse compartment.
3. Take the old fuse out and replace it with a new one of the same type (230 V / 500 mA,
slow blowing).
Care and cleaning
• Disconnect the product from the power supply before cleaning.
• Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as
they can cause damage to the housing and malfunctioning.
• Clean the product with a dry, ber-free cloth.
• Do not immerse the product in water.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product according to
the relevant statutory regulations.
You thus full your statutory obligations and contribute to the protection of the
environment.
Technical data
Operating voltage ......................... 230 V/AC, 50 Hz
Output voltage/current .................. +5 V/DC (xed), 1 A
0 to +15 V/DC (variable), 500 mA
0 to -15 V/DC (variable), 500 mA
Number of terminal posts ............. 4
Terminal post dimensions ............. 4 x 4 mm
Number of contact points .............. 2390
Fuse .............................................. 230 V / 500 mA; slow blowing
Dimensions (W x H x D) ............... 200 x 80 x 250 mm
Weight .......................................... approx. 2.43 kg