Connecting Electrical Loads
1. Let engine stabilize and warm up for a few minutes
after starting.
2. EnsuremainbreakerisinOn” position.
3. Pluginandturnonthedesired120and/or240Volt
AC,singlephase,60Hzelectricalloads.
NOTICE When plugging into the 120 Volt receptacles, plug
items to be powered in sequence as shown below.
NOTICE
 • DO NOTconnect240Voltloadsto120Voltduplex
receptacles.
 • DO NOT connect 3-phase loads to generator.
 • DONOTconnect50Hzloadstogenerator.
 • DONOTOVERLOADTHEGENERATOR.SeeDon’t
Overload Generator.
NOTICE
Exceeding generators wattage/amperage capacity
could damage generator and/or electrical devices connected
to it.
• DO NOT exceed the generator’s wattage/amperage capacity. See
Don’t Overload Generator in the Operation section.
• Startgeneratorandletenginestabilizebeforeconnectingelectrical
loads.
• ConnectelectricalloadsinOFFposition,thenturnONfor
operation.
• TurnelectricalloadsOFFanddisconnectfromgeneratorbefore
stopping generator.
Stopping the Engine
1. Turn OFF and unplug all electrical loads from generator
panel receptacles. NEVER start or stop engine with
electrical devices plugged in and turned ON.
2. Let engine run at no-load for several minutes to
stabilize internal temperatures of engine and generator.
3. Push engine switch to OFF (O) position.
4. MovefuelvalvetoOff” position.
Low Oil Shutdown
If the engine oil drops below a preset level, an oil switch will
stop the engine. Check oil level with dipstick.
If oil level is between ADD and FULL mark on dipstick:
1. DO NOT try to restart the engine.
2. Contact an Authorized Briggs & Stratton Service Dealer.
3. DO NOT operate engine until oil level is corrected.
If oil level is below ADD mark on dipstick:
1. Add oil to bring level to FULL mark.
2. Restart engine and if the engine stops again a low oil
condition may still exist. DO NOT try to restart the
engine.
3. Contact an Authorized Briggs & Stratton Service Dealer.
4. DO NOT operate engine until oil level is corrected.
Cold Weather Operation
Under certain weather conditions (temperatures below 40°F
[4°C] combined with high humidity), your generator may
experience icing of the carburetor and/or the crankcase
breather system. To reduce this problem, you need to
perform the following:
1. Make sure generator has clean, fresh fuel.
2. Open fuel valve (turn valve to open position).
3. Use SAE 5W-30 oil.
4. Check oil level daily or after every eight (8) hours of
operation.
5. Maintain generator following Maintenance Schedule in
Maintenance section.
6. Shelter unit from elements.
WARNING Fuel and its vapors are extremely flammable
and explosive which could cause burns, fire
or explosion resulting in death or serious
injury.
• DONOTstopenginebymovingchokelevertoChoke” position
( ).