Operation Manual
8 EN
tower fan TVE 36 T
Remote control
All settings of the device can also be made using the remote
control included in the scope of delivery.
16
7
9
15
8
14
No. Designation Meaning
16 Remote control
transmitter/
receiver
For infrared transmission to the
device
7 ON/OFF button Switching the device on and off
9 TIMER button Timer function for switch-on and
switch-off
Setting the number of hours of the
activated timer
15 MODE button Selecting the operating mode:
normal operation
natural wind
night mode
8 OSC button Activating and deactivating the
oscillation function
14 Fan stage button • Setting the fan stage (1-3)
stage1 = low fan speed
stage2 = medium fan speed
stage3 = high fan speed
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Switch off the device.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Clean the device according to the Maintenance chapter.
• Store the device according to the Storage chapter.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
• Check the power connection.
• Check the power cable and mains plug for damages.
• Check the on-site fusing.
• Check whether the overheating protection has tripped, see
chapter Safety.
• Wait for 10minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The fan does not start:
• Check whether the unit is switched on.
• Check the power supply and whether the plug or cable is
defective.
The device is loud or vibrates:
• Check whether the device is set up in a stable and upright
position.
• Check whether the device is mounted correctly.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.