Operation Manual

EN Operating Manual – Dehumidifier TTR 56 E 9
Shutdown
1. Press the POWER button (46).
The operation indicator light (44) flashes during rundown
operation (approx. 2 minutes), then goes out.
2. Wait until the end of the rundown period (approx. 2 minutes).
– Due to the follow-up time of the internal components, the
device only switches off completely after approx. 2
minutes.
3. Do not touch the mains plug with wet or damp hands.
4. Do not pull the mains plug from the mains socket before the
rundown operation is completed.
5. Empty the condensation tank and wipe it dry with a clean
cloth. Check for dripping condensation.
6. Clean the device, and especially the air filter, according to the
chapter Maintenance.
7. Store the device according to chapter Storage.
The accurate functionality of the device was tested during
production a number of times. However, if functionality faults do
occur, then check the device according to the following list.
The device does not start or has been switched off:
Check the power connection.
Check the mains plug for damages.
Check that the condensation tank is positioned correctly.
Check the filling level of the condensation tank and empty it,
if necessary. The condensation tank indicator light (45) must
not light up.
The device comes equipped with a tilt protection, it switches
off automatically when tilted. The operation indicator
light (44) must be illuminated in green. When the lamp
flashes, check whether device is in an upright position on a
level surface.
Have the electrics checked by a specialist company for
cooling and air-conditioning or by Trotec.
The device is running, but forms no condensate:
Check the float in the condensation tank for dirt. If necessary,
clean the float and condensation tank. The float must be able
to move freely.
Check the room temperature. Observe the device's
permissible operating range according to the technical data.
Check the selected operation mode and the programmed
nominal humidity value.
Ensure that the relative humidity complies with the technical
data.
Check the air filter for dirt. If necessary, clean or replace the
air filter.
From the outside, check the condenser for dirt (see chapter
Maintenance). If your condenser is dirty, have it cleaned by a
specialist company for cooling and air-conditioning or by
Trotec.
The device is loud or vibrates; condensate is leaking:
Check whether the device is standing upright and on an even
surface.
The device gets very warm, is loud or is losing performance:
Check air inlets and air filter for dirt. Remove external dirt.
Visually examine the inside of the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and
air-conditioning or by Trotec.
Your device still does not operate correctly after these
checks?
Bring the device to a specialist company for cooling and
air-conditioning or to Trotec for repair.
Errors and faults