Circuit diagram TTR 400D
PE
air-dehumidifier TTR 400D
no./rev.
Titel
E-EA-400D-0011/02
Trotec GmbH & Co.KG Grebbenerstr.7, 52525 Heinsberg
transmission and copying of this
document and exploitation of its
contents is not permitted.
M
~
M
~
S1
12
34
R1
M
~
E1/ge
GND/bl
L1/bl
N/bl
DC Out/rt
21 22
1
2
C1
A
K1
XB1
LinLout N
Stundenzähler
Optional
43 2 1
M1
M3
3
4
N
L
PE
230V
-
+
GND 24V+
PWM
PWM GND 24V+
M
24VDC
+
-
M2
ge
ge
rt
E1 E2
Lin N
Stundenzähler
43 12
K1
K1
11 12
0,15µF
0-10/20A
A1
P1
P2
T1
Sw
Gehäuse/housing
230VAC
<16A
PE
XB3
kWh
G1
1
3
3
XS1
2
43
2 1
XS3
PE/gg
r.H
32 1
Hygrostat
Optional
XS2
3 2 1 PE
XB2
3 12 PE
Symbol
M1
M2
A1
E1,E2
C1
S1
P1
T1
M3
operation time+energy counter
Benennung
fan ADS
fan REG
capacitor
ptc-heater
operation time counter
main-switch
ammeter
rotor drive
power supply
P2
potentiometer
power relay
G1
K1
24VDC
sw=schwarz/black
rt=rot/red
ge=gelb/yellow
bl=blau/blue
gg=gelb-grün