Operation Manual

EN 6
Operating manual – dehumidifier TTK 75 S
Inserting the air filter
Note
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Make sure that the air filter is installed before switching
the device on.
Inserting the condensation tank
Ensure that the float inside the condensation tank is
inserted correctly.
Ensure that the condensation tank is empty and inserted
correctly.
Connecting the power cable
Insert the mains plug into a properly secured mains
socket.
Operation
Avoid open doors and windows.
After being switched on, the device operates fully
automatically.
The fan permanently runs in dehumidification mode even
after the set nominal value has been reached until the
device is switched off.
Operating elements
14 151312
No. Designation Meaning
12 FULL indication Is displayed when the
condensation tank is full or not
installed correctly.
13 Selector switch For the selection of the
performance level:
H= high fan speed
(laundry drying function)
L= low fan speed
14 Rotary switch For the selection of the desired
relative humidity level:
MIN= low humidity level
(up to 30%)
MAX= high humidity level
(up to 90%)
15 POWER indication Is displayed after the device has
been switched on.
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
1. Switch the device on at the on/off switch(4).
ð The unit starts to dehumidify.
ð The POWER indication(15) is illuminated.
Setting the operating mode
Setting the desired relative room humidity
You can change the desired relative room humidity at any time.
1. Adjust the humidity level as desired by setting the rotary
switch(14) to a position between MIN and MAX.
Setting the fan speed
You can choose between low and high fan speed (laundry drying
function) at any time.
1. Turn the selector switch(13) to the desired fan speed.