Technical data
Parameter Value
Model TTK 75 S
Max. dehumidification
performance
24 l / 24 h
Air volume 180 m
3
/h
Operating range (temperature) 5°C to 35°C
Operating range
(relative humidity)
30% to 90%RH
Pressure suction side 1MPa
Pressure outlet side 2MPa
Power supply 1/N/PE ~ 220 – 240V/ 50 Hz
Power consumption, max. 0.33 kW
Nominal current 1.5 A
Refrigerant R-134a
Amount of refrigerant 170 g
GWP factor 1,430
CO
2
equivalent 0.24 t
Water tank capacity 3.6 l
Sound pressure level 40 dB(A)
Dimensions
(lengthx widthx height)
300 x 350 x 585 mm
Minimum distance to walls and
other objects
A: top:
B: rear:
C: side:
D: front:
30 cm
20 cm
20 cm
20 cm
Weight 13 kg
Disposal
The icon with the crossed-out waste bin on waste
electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.
The device is operated with fluorinated greenhouse gas which
can be dangerous for the environment and contribute to global
warming when emitted to the atmosphere.
Further information is provided on the nameplate.
Dispose of the refrigerant appropriately and according to the
national regulations.