TTK 75 S EN TRT-BA-TTK75S-TC-003-EN OPERATING MANUAL DEHUMIDIFIER
You can download the current version of the operating manual and the EU declaration of conformity via the following link: Table of contents Notes regarding the operating manual................................. 1 Safety ..................................................................................... 1 Information about the device................................................ 3 TTK 75 S Transport and storage........................................................... 4 Assembly and installation......
• • • • • • • • • • • • EN Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged! The electrical connection must correspond to the specifications in chapter Technical data. Insert the mains plug into a properly secured mains socket. Observe the device's power input, cable length and intended use when selecting extensions to the power cable.
Residual risks Information about the device Warning of electrical voltage Work on the electrical components must only be carried out by an authorised specialist company! Warning of electrical voltage Before any work on the device, remove the mains plug from the mains socket! Hold onto the mains plug while pulling the power cable out of the mains socket.
Device depiction 11 1 2 3 10 No. Designation 1 Air outlet (top) 2 Control panel 3 Condensation tank with filling level indicator 4 On/off switch 5 Air inlet with air filter 6 Condensation drain hose connection 7 Power cable winder 8 Wheels 9 Air filter 10 Air outlet (side) 11 Transport handle Transport and storage 4 5 6 7 8 9 Note If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.
Storage Start-up Before storing the device, observe the following: • Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance). • Empty and clean the condensation tank prior to storage. • Drain any possibly remaining condensate.
Operating elements Inserting the air filter • Note Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device. Make sure that the air filter is installed before switching the device on. Inserting the condensation tank • Ensure that the float inside the condensation tank is inserted correctly.
Dehumidification The device keeps running until reaching the desired relative room humidity. Then the compressor switches off and the fan keeps running. Once the desired relative room humidity is exceeded, the compressor switches back on. The desired relative room humidity can be adjusted at any time. You can choose between low and high fan speed (laundry drying function). 3. Take the condensation tank out of the device.
5. Refit the condensation tank into the device. Make sure not to damage the float when inserting or removing the condensation tank. In doing so, make sure that the float is positioned correctly. In doing so, make sure that the condensation tank is inserted correctly, for otherwise the device cannot be switched back on. Automatic defrost At low ambient temperatures (below 15 °C), ice may form at the evaporator during dehumidification.
Errors and faults The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list. The device does not start: • Check the power connection. • Check the power cable and mains plug for damages. • Check the on-site fusing. • Check the filling level of the condensation tank and empty it if necessary. The FULL indication (12) must not light up. • Check the condensation tank for correct seating.
Maintenance intervals Maintenance Maintenance and care interval Check air inlets and outlets for dirt and foreign objects and clean if necessary before every start-up as needed at least every at least every at least every at least 2 weeks 4 weeks 6 months annually X X Clean the exterior X X Visually check the inside of the device for dirt X X Check the air filter for dirt and foreign objects and clean or replace if necessary X X X Replace the air filter Check for damage Check the attachment
Maintenance and care log Device number: .................................... Device type: .............................................
Activities required before starting maintenance • • Warning of electrical voltage Do not touch the mains plug with wet or damp hands. Switch the device off. Hold onto the mains plug while pulling the power cable out of the mains socket. Warning of electrical voltage Tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec. Cleaning the air filter Note Ensure that the air filter is not worn or damaged.
4. Refit the condensation tank into the device. Make sure not to damage the float when inserting or removing the condensation tank. In doing so, make sure that the float is positioned correctly. Also make sure that the condensation tank is inserted correctly, otherwise the device cannot be switched back on. 4. Reinsert the air filter into the device.
Technical annex Disposal Technical data Parameter Value Model TTK 75 S Max. dehumidification performance 24 l / 24 h Air volume 180 m3/h Operating range (temperature) 5 °C to 35 °C Operating range (relative humidity) 30 % to 90 % RH Pressure suction side 1 MPa Pressure outlet side 2 MPa Power supply 1/N/PE ~ 220 – 240 V / 50 Hz Power consumption, max. 0.33 kW Nominal current 1.5 A Refrigerant R-134a Amount of refrigerant 170 g GWP factor 1,430 CO2 equivalent 0.