TTK 40 E EN TRT-BA-TTK40E-TC-003-EN OPERATING MANUAL DEHUMIDIFIER
You can download the current version of the operating manual and the EU declaration of conformity via the following link: Table of contents Notes regarding the operating manual................................. 1 Safety ..................................................................................... 1 Information about the device................................................ 3 TTK 40 E Transport and storage........................................................... 4 Assembly and installation......
• • • • • • • • • • • • • Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged! The electrical connection must correspond to the specifications in chapter Technical data. Insert the mains plug into a properly secured mains socket. Observe the device's power input, cable length and intended use when selecting extensions to the power cable. Completely unroll extension cables.
Behaviour in the event of an emergency 1. Switch off the device. 2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket. 3. Do not reconnect a defective device to the mains. 3 Information about the device Description of the device The device uses the principle of condensation to automatically dehumidify rooms.
Device depiction Transport and storage Note If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device. 1 2 Transport 3 To make the device easier to transport, it is fitted with wheels. To make the device easier to transport, it is fitted with a carry handle. Before transporting the device, observe the following: • Switch the device off. • Hold onto the mains plug while pulling the power cable out of the mains socket.
Assembly and installation • Scope of delivery • • • • 1 x Device 1 x Air filter 1 x Manual Make sure that no curtains or other objects interfere with the air flow. When positioning the device, particularly in wet areas, secure it locally with an RCD (residual current device) which complies with the respective regulations. Inserting the air filter Unpacking the device 1. Open the cardboard box and take the device out. 2. Completely remove the packaging. 3. Fully unwind the power cable.
Operation Notes: • Avoid open doors and windows. • After being switched on, the device operates fully automatically. • The fan is running continuously until the device is switched off. 10 Meaning 19 Fan speed indication HIGH: high fan speed (laundry drying function) LOW: low fan speed 20 TIMER button For activating the timer (2 or 4 hours) 21 Timer indication Indicates the number of hours for the timer (2 or 4 hours).
3. Remove the rubber plug. Setting the timer The timer has the following functionality: • automatic switch-off upon expiry of a preset number of hours (2 h or 4 h). Note Do not leave the operating device unattended in a freely accessible room with an activated timer. Automatic switch-off ü The device is switched on. 1. Press the TIMER button (20) until the LED for the desired number of hours (2 h or 4 h) is illuminated. 2. Wait for approx. 5 seconds in order to save the setting.
6. Screw the adapter for the condensation drain hose onto the hose connection. 7. Push one end of the hose onto the adapter. Drying laundry In addition, the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces. When positioning the device or a clothes horse, please observe the minimum distances specified in the technical data.
Errors and faults The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list. The device does not start: • Check the power connection. • Check the power cable and mains plug for damages. • Check the on-site fusing. • Check the filling level of the condensation tank and empty it if necessary. The TANK FULL LED (12) must not light up. • Check the condensation tank for correct seating.
Maintenance intervals Maintenance Maintenance and care interval Check air inlets and outlets for dirt and foreign objects and clean if necessary before every start-up as needed at least every at least every at least every at least 2 weeks 4 weeks 6 months annually X X Clean the exterior X X Visually check the inside of the device for dirt X X Check the air filter for dirt and foreign objects and clean or replace if necessary X X X Replace the air filter Check for damage Check the attachment
Maintenance and care log Device number: .................................... Device type: .............................................
Activities required before starting maintenance • • Cleaning the air filter Warning of electrical voltage Do not touch the mains plug with wet or damp hands. Switch the device off. Hold onto the mains plug while pulling the power cable out of the mains socket. Warning of electrical voltage Tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec. Cleaning the housing Note Ensure that the air filters are neither worn nor damaged.
3. Allow the filter to dry completely. Do not insert a wet filter into the device! 4. Reinsert the air filter into the device. 5. Press the FILTER button (15) to reset the FILTER RESET LED (14). Emptying the condensation tank When the condensation tank is full or not inserted correctly, the device stops dehumidification operation and switches itself off. The TANK FULL indication (12) is illuminated. 1. Take the condensation tank out of the device. 2. Empty the condensation tank over a drain or sink. 3.
Technical annex Disposal Technical data Parameter Value Model TTK 40 E Dehumidification performance 14 l / 24 h at 32 °C and 80 % RH Air volume 100 m3/h Operating range (temperature) 5 °C to 35 °C Operating range (relative humidity) 30 % to 100 % RH Pressure suction side 0.6 MPa Pressure outlet side 1.7 MPa Power supply 230 V / 50 Hz Power consumption max. 340 W Nominal current consumption 1.5 A Refrigerant R-134a Amount of refrigerant 90 g GWP factor 1,430 CO2 equivalent 0.
Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.