Operation Manual

2 Operating manual – Condenser dryer DH 75/110 AX/BX EN
Description of the device
This device uses the principle of condensation to automatically
dehumidify rooms.
The fan sucks damp room air through the air inlet (6), the evapo-
rator and to the condenser located behind it. The air is cooled at
the cold evaporator until it is below the dew point. Water vapour
contained in the room air precipitates on the evaporator fins as
either condensation or frost. The dehumidified, cooled air is
rewarmed at the condenser and blown out at a temperature of
approx. 5 °C above room temperature. The drier air, thus condi-
tioned, mixes with the air in the room via the air outlet (7). The
humidity in the room where the device is positioned is reduced as
air constantly circulates through the device. Depending on the air
temperature and the relative humidity, the condensed water either
drops continuously or only during the defrost phase into the con-
densation tray. The condensate is discharged from the device via
a condensation drain hose (5).
Located on top of the device underneath the protective cover is a
control panel (1). To be found there is a hygrostat with control dial
to adjust the desired humidity level. This control dial can be easily
accessed once the protective cover has been removed.
The device can reduce the relative humidity of a room by up to
approx. 30 %. Because of the heat radiation which is tied up in
operation, the room temperature can rise by approx. 1-3 °C.
Device depiction
Note!
If you have further questions on how to use heat recovery, please
contact your TROTEC
®
customer service.
Scope of delivery
Condenser dryer DH 75/110 AX/BX
condensation drain hose
Operating manual
Information about the device
No. Operating element
1 control panel and control box (underneath the protective cover)
2 connection for power cable
3 connection for water outlet when using heat recovery (optional with the
respective models)
4 connection for water inlet when using heat recovery (optional with the
respective models)
5 hose connector for condensation drain hose
6 air inlet
7 air outlet
1
2
7
5
6
3
4