Operation Manual

10 Operating manual – Condenser dryer DH 75/110 AX/BX EN
The accurate functionality of the device was tested during produc-
tion a number of times. However, if functionality faults do occur,
then check the device according to the following list.
The device does not start:
Check the mains connection (see chapter Technical data).
Check the power cable for damages.
Check the fuse (home).
Check the preselected humidity level at the hygrostat's control
dial. The humidity in the room must be above the selected
range. Reduce that the selected relative humidity.
Have the electrics checked by a specialist company for cooling
and air-conditioning or by TROTEC
®
.
The device runs but forms no condensation:
Check the condensation drain hose is positioned correctly.
Check that the condensate pump functions properly. Check for
abnormal vibrations and sounds. Remove external dirt.
Check the room temperature. Check the device's permissible
operating range complies with the technical data.
Ensure that the relative humidity complies with the technical
data.
Check the preselected humidity level at the hygrostat's control
dial. The humidity in the room must be above the selected
range. Reduce that the selected relative humidity.
Check the air filter is not dirty. If necessary, clean or replace
the air filter.
The device is loud or vibrates; condensation leaks:
Check, whether the device is mounted horizontally.
The device gets very warm, is loud or is losing performance:
Check the air inlets and air filter are not dirty. Remove external
dirt.
Check the inside of the device for dirt (see chapter Mainte-
nance). If necessary, clean the interior of the device using
compressed air.
Your device still does not operate correctly after these
checks?
Bring the device to a specialist company for cooling and air-con-
ditioning or to TROTEC
®
for repairs.
Errors and faults