Operation Manual

EN Operating manual – Condenser dryer DH 75/110 AX/BX 9
Switch device on
1. Ensure that the condensation drain hose has been laid and
connected properly. Do not create tripping hazards.
2. Ensure that the condensation drain hose is not bent or
jammed and that there are no objects on the condensation
drain hose.
3. Ensure that the condensation can run off properly.
4. Only have the power cable connected to the terminal block of
the control box (underneath the protective cover) by an elec-
trically skilled person!
5. Check whether the operation indicator light (14) lights up.
6. Set the desired fan speed using the flip switch (11).
Room humidity adjustment
Set the desired humidity level via the control dial (13) of the hygro-
stat. The built in hygrostat switches dehumidification back on or
off depending on the relative humidity.
Automatic defrost
If the room temperature is below 15 °C, the evaporator becomes
covered in frost during dehumidification. The device then carries
out an automatic defrost. The automatic defrost indicator light (12)
is lit. The fan stops operating during automatic defrost. The dura-
tion of the defrost can vary.
Shut down procedure
1. Only have an electrically skilled person disconnect the power
cable!
2. Remove the condensation drain hose and any residual fluid
from it.
3. Clean the device, and especially the air filter, according to
chapter Maintenance.
4. Store the device according to chapter Storage.