User Manual

EN 9
condenser dryer DH 105 S / DH 115 S / DH 145 SH
Mains connection
A 3/N/PEthree-phase socket with clockwise rotating field is
required to connect the device. The device is delivered with
a CEEphase inverter, 32A, 6h.
Insert the plug into the respective CEEsocket.
If the device does not start up automatically and the error
messageE5 appears in the segment display, the rotating field in
the phase inverter must be corrected.
Correct the rotating field in the phase inverter as follows:
1. Pull the plug from the mains socket.
2. Use a suitable flat-head screwdriver.
3. Rotate the element for phase inversion by 180°.
ð Phases are now inverted.
180°
4. Plug the plug back into the socket.
Operation
Avoid open doors and windows.
After being switched on, the device operates fully
automatically.
The fan runs permanently until the set nominal value is
reached or the device switched off.
Control panel DH105S/ DH115S
12
13 14
15
16
17
18
No. Designation Meaning
12 Segment display Display of the selected humidity in
percentage or CO for continuous
operation mode (value<30%)
(The default value is60%RH.)
Display of error codes
13 MEMORYLED Illuminated when the current humidity
setting is saved.
14 HUMIDITY UP
button
Increasing the desired relative room
humidity
For deactivating continuous operation
HUMIDITY DOWN
button
Decreasing the desired relative room
humidity
For activating continuous operation
15 ON/OFF button Switching the device on and off
16 MEMORY button Saves the current humidity setting.
17 DEFROSTINGLED Illuminated when automatic defrosting
is in progress.
18 OPERATION LED Illuminated during ongoing operation.