User Manual
Table Of Contents
8 EN
condenser dryer DH 105 S / DH 115 S / DH 145 SH
Positioning the condensation drain hose
For continuous operation or unattended dehumidification, please
connect the supplied condensation drain hose to the device.
ü A suitable hose (diameter: 15mm) is ready for use.
ü The device is switched off.
1. Connect the condensation drain hose to the condensation
hose connection(6) at the device.
2. Make sure that the condensation drain hose is properly
connected to the device and free of damage.
3. Depending on the application, position the end of the
condensation drain hose as follows:
ð Place a sufficiently dimensioned container (at least
90litres) beside the device and insert the hose end.
Check the filling level of the container regularly.
ð Position the end of the condensation drain hose above a
water drain. For larger distances, a longer hose of the
same type can also be used.
Removing the condensation drain hose
Press the blue ring on the outside of the quick coupling together
and at the same time pull the hose.