User Manual
Table Of Contents
10 EN
condenser dryer DH 105 S / DH 115 S / DH 145 SH
Operating elements DH145SH
19 20 21
No. Designation Meaning
19 Humidity control
dial
Switching the device on and off
Setting the desired relative room
humidity
For activating continuous operation
20 OPERATION
indicator light
Illuminated during ongoing operation.
21 ALARM indicator
light
Illuminated when the wrong rotating
field is set in the mains plug.
Operating elements condensate pump
3
4
No. Designation Meaning
3 Residual water
draining button
For draining residual condensate from
the condensation tray (optional)
4 Condensation tray
indicator light
Illuminated and emits an acoustic
signal when the condensation tray is
full (optional).
Switching the device on
Once you have completely installed the device as described in
the chapter Assembly and start-up, you can switch it on.
DH 105 S / DH 115 S:
1. Press the ON/OFFbutton(15).
ð The device is switched on.
ð The OPERATION LED(18) is illuminated.
2. Press the ON/OFF button(15) again to switch the device
off.
The device switches off automatically when the condensation
tray is full. The condensation tray indicator light(4) lights up and
the buzzer emits an acoustic signal.
DH145SH:
1. Turn the humidity control dial(19) clockwise.
ð The device is switched on.
2. Turn the humidity control dial(19) counter-clockwise into
the positionOff(0) to switch the device off.
The device switches off automatically when the condensation
tray is full. The condensation tray indicator light(4) lights up and
the buzzer emits an acoustic signal.
Setting the desired room humidity
DH 105 S / DH 115 S:
The desired relative room humidity can be preselected.
1. Repeatedly press the buttons HUMIDITYUP(14) or
HUMIDITYDOWN(14) to select the desired relative
humidity value. Setting is possible in the range between
30% and 90%.
ð The desired relative humidity level is indicated on the
segment display(12).
The device keeps running until reaching the desired relative
room humidity.
Once the desired relative room humidity is exceeded, the
compressor and fan switch back on.