Specifications
U1-AGM DATA SHEET
TRJN_U1-AGM_DS_0315
Page 1 of 2
CHARGING INSTRUCTIONS
MODEL: U1-AGM
VOLTAGE: 12
DIMENSIONS: Inches (mm)
BATTERY: VRLA AGM
COLOR: Maroon (case/cover)
MATERIAL: Polypropylene
WATERING SYSTEM: N/A
DESIGN LIFE: 10 Years
PRODUCT SPECIFICATIONS
OPERATIONAL DATA
Operating Temperature Self Discharge
-4°F to 131°F (-20°C to +55°C). At temperatures
below 32°F (0°C) maintain a state of charge
greater than 60%.
Less than 3% per month depending
on storage temperature conditions.
CHARGER VOLTAGE SETTINGS (AT 77°F/25°C)
System Voltage 12V 24V 36V 48V
Absorption Charge 14.1 – 14.7 28.2 – 29.4 42.3 – 44.1 56.4 – 58.8
Float Charge 13.5 27 40.5 54
Do not install or charge batteries in a sealed or non-ventilated compartment. Constant
under or overcharging will damage the battery and shorten its life as with any battery.
CHARGING TEMPERATURE COMPENSATION
.028 VPC for every 10°F (5.55°C) above or below 77°F (25°C) (add .028 VPC for every
10°F (5.55°C) below 77°F and subtract .028 VPC for every 10°C above 77°F).
BCI
GROUP
SIZE
TYPE
CAPACITY
A
Minutes
CRANKING Performance CAPACITY
B
Amp-Hours (AH)
ENERGY
(kWh)
TERMINAL
Type
G
DIMENSIONS
C
Inches (mm)
WEIGHT
lbs. (kg)
@25 Amps
C.C.A.
D
@0°F
C.A.
E
@32°F
5-Hr Rate 10-Hr Rate 20-Hr Rate 100-Hr Rate 100-Hr Rate Length Width
Height
F
12 VOLT DEEP CYCLE AGM BATTERY
U1 U1-AGM 42 240 306 29 31 33 34 0.408 13 7.78 (198) 5.20 (138) 6.75 (171) 27 (12)
A. The number of minutes a battery can deliver when discharged at a constant rate at 80°F (27°C) and maintain a voltage above 1.75 V/cell. Capacities are based on peak performance.
B. The amount of amp-hours (AH) a battery can deliver when discharged at a constant rate at 80°F (27°C) and 86°F (30°C) for the 5-Hour rate and maintain a voltage above 1.75 V/cell. Capacities are based on
peak performance.
C. Dimensions are based on nominal size. Dimensions may vary depending on type of handle or terminal. Batteries to be mounted with .5 inches (12.7 mm) spacing minimum.
D. C.C.A. (Cold Cranking Amps) - the discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 0°F at a voltage above 1.2 V/cell.
E. C.A. (Cranking Amps) - the discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32°F at a voltage above 1.2 V/cell. This is sometimes referred to as marine cranking
amps @ 32°F or M.C.A. @ 32°F.
F. Dimensions taken from bottom of the battery to the highest point on the battery. Heights may vary depending on type of terminal.
G. Terminal images are representative only.
Trojan’s battery testing procedures adhere to BCI-05 (Rev Oct 09) and IEC 61427 test standards.
TERMINAL CONFIGURATIONS
13 IT Insert Terminal
Terminal Height Inches (mm)
.19 (4.7)
Torque Values in-lb (Nm)
30 (3 – 4)
Bolt Size
10-32UNF