User manual
IRIS Starter kit - Test program
IRIS-Starter kit-Test programl-1a
2
I/O event
An I/O event is trigged when one, or more, of the inputs, the outputs and/or the fl ags match a
predefi ned bit pattern.
Input 1-5 is digital in this setup
• Input 1 goes high
• Send a message to the other unit to set Output 1 high
• Input 2 goes high
• Send Message number 1 to the other unit.
• Input 3 goes high
• Increase Counter 1 with 1
• Input 4 goes high and Input 5 goes high
• Send Message number 2 to the serial interface
• Input 5 goes high
• Start Timer 1
Input 6 is analogue in this setup
• Input 6 lower limit = 10V ±1V (Hysteres = 2V)
• Send Message 3 to the other unit.
• Input 6 upper limit= 20V ±1V (Hysteres = 2V)
• Send Message 4 to the other unit.
Output
(diodes)
Input
(buttons)
External I/O