IRIS Configuration - Manual
IRIS-Confi g-Manual-1a
8
Serial communication setup
Any changes in the serial communication setup can have effect on the possibility of future
changes of the setting.
Baudrate
• The baudrate is between 300 and 115200 baud.
• Default:
• 9600 baud
Parity
• Uses odd, even or no parity.
• Default:
• No parity
Stop bit
• The IRIS-unit handles 1 or 2 stop bits
• Default:
• 1 stop bit
Protocol
The current version of fi rmware in the IRIS-unit supports:
• RS-232
• RS-485 full duplex
• RS-485 half duplex
In future versions:
• IRIS to IRIS protocol
• Makes it possible to connect two IRIS-units via the serial interface instead of radio.
Timeout / Detect end of text
A timeout after the last character is one way of determine when a text is fully received.
• Possible timeouts:
• 50ms, 100ms, 200ms, 500ms, 1s and 2s
“Detect end of text” uses a sequence of one or two characters to determine when a text is ful-
ly received. To enable the use of non-printable characters the IRIS-unit uses the ASCII-codes
for the characters, the decimal value. It is possible to use one of the predefi ned sequences or
enter a user-defi ned sequence.
• Predefi ned sequences:
• 13,10 (CRLF), 13 (CR), 10 (LF) and 3 (ETX)
It is possible to use both “Timeout” and “Detect en of text” at the same time.