Any changes in the serial communication setup can have effect on the possibility of future
changes of the setting.
Baudrate
The baudrate is between 300 and 115200 baud.
Default:
9600 baud
Parity
Uses odd, even or no parity.
Default:
No parity
Stop bit
The IRIS-unit handles 1 or 2 stop bits
Default:
1 stop bit
Protocol
The current version of fi rmware in the IRIS-unit supports:
RS-232
RS-485 full duplex
RS-485 half duplex
In future versions:
IRIS to IRIS protocol
Makes it possible to connect two IRIS-units via the serial interface instead of radio.
Timeout / Detect end of text
A timeout after the last character is one way of determine when a text is fully received.
Possible timeouts:
50ms, 100ms, 200ms, 500ms, 1s and 2s
“Detect end of text” uses a sequence of one or two characters to determine when a text is ful-
ly received. To enable the use of non-printable characters the IRIS-unit uses the ASCII-codes
for the characters, the decimal value. It is possible to use one of the predefi ned sequences or
enter a user-defi ned sequence.
Predefi ned sequences:
13,10 (CRLF), 13 (CR), 10 (LF) and 3 (ETX)
It is possible to use both “Timeout” and “Detect en of text” at the same time.