User manual

15
* Thespeedlevelsonthelocomotivedecoderandonthecontrollermustagreewitheachother;otherwise,
you may have malfunctions.
CV Discription DCC Value Factory-Set
1 Address 1 - 127 3
2 PoM Minimum Speed 0 - 255
5
3 PoM Acceleration delay 0 - 255
18
4 PoM Braking delay 0 - 255
18
5 PoM Maximum speed 0 - 255
190
8 Factory Reset / Manufacturer Recognition 8 131
13 PoM Functions F1 - F8 in analog operation 0 - 255 0
14 PoM Functions F9 - F15 and lights in analog operation 0 - 255 1
17 Extended address (upper part) CV29,Bit5=1 192
18 Extended address (lower part) CV29,Bit5=1 128
19 Multiple Unit Address 0 - 255 0
21 PoM Functions F1 - F8 on Multiple Unit 0 - 255 0
22 PoM Functions F9 - F15 and lights on Multiple Unit 0 - 255 0
29 PoM
Bit0:Reversingdirectionoftravel
Bit1:Numberofspeedlevels14or28/128*
Bit2:DCCoperationwithabrakingarea(noanalogoperation
possible)
Bit5:short/longaddress
0 / 1
0 / 2
0 / 4
0 / 32
0, 1, 2, 3, 4, 5, 6,
7, 32, 34, 35, 36,
37, 38, 39
6
50 PoM
Alternative Protocols (DCC cannot deactivate itself)
Bit0:AnalogACoff=0/AnalogACon=1
Bit1:AnalogDCoff=0/AnalogDCon=1
Bit2:fx(MM)off=0/fx(MM)on=1
Bit3:mfxoff=0/mfxon=1
0 / 1
0 / 2
0 / 4
0 / 8
0 - 15 15
63 PoM Volume 0 - 255 255