CONTENTS HISTORY, PRODUCTION 4 Clothes Lockers and Cloak room equipment 6 Marketing 12 VARIABILITY 14 FREE-STANDING CABINETS 15 – for maximum user’s comfort 17 RMA RZA – demountable 25 RDA – server cabinet with loading capacity 1000 kg 31 RDE – server cabinet with IP 54 and loading capacity 1000 kg 37 RIE – protection against harmful effect of water and dust (IP 54) 43 RPE, RPA – for industrial environment 49 ROA – with a rotating inner frame 53 RSX – 19” open frames 57 DATA CENTERS 61 – data c
2009 TRITON – Starý Mateřov PRODUCTION – MANUFACTURING PROGRAM The second stage of our works on fully automated production line TRITON Pardubice is going to be finished in 2011. Up-to-date high technology for sheet metal processing, bending centers, robot welding lines, new powder coating line and further sophisticated takeworkplaces enable us to become the leader in European market in the field of 19“ cabinets and clothes lockers.
and ISO 14001. Your personal visit in our factory will persuade you of the fact, that we take these standards really seriously. You are heartily welcome ! You will find a complete product range of 10“, 19“ and 21“ data and telecommunication cabinets TRITON in the new catalogue published for the trade fair Cebit 2011.
Clothes Lockers and Cloak room equipment Due to the development of our factory building and modernization of our production process we launched a new range of products - Clothes Lockers, in 2008. The lockers are of metal construction with door and walls of laminated chipboard, eventually they are fully made of steel plates. All metal components have powder-paint finish which assure a long-term operating life of our lockers and easy maintanence.
Our regular customers are hospitals, schools, fitness facilities, companies, swimming pools, etc. We are at your disposal for any questions: e-mail: info@clotheslockers.eu phone: +420 467 401 111 web sites: www.clotheslockers.eu www.garderobenspinde.de www.satniskrinky.
8
9
10
11
CeBIT 2010 – Hannover MARKETING – TRADE FAIRS Company TRITON has long time experience with trade fairs. Our first company` s presentation was trade fair INVEX in 1995, which we joined four times in a sequence. Since the year 1998 we have been regularly participating on CeBIT trade fair in Hannover, the biggest European event of AMPER 2010 – Praha 12 information technologies. We have been also regularly joining trade fair AMPER since 2007.
MARKETING – SHOW TRUCK In order to improve our support, we have purchased a mobile presentation workplace which is ready to go out to your current important or potential clients and to present the TRITON company products. Hereby we want to support your sales activities which we highly appreciate. The van in the photographs is equipped with an up-to-date presentation technology, samples of the TRITON products, a bar and a room for making refreshments.
VARIABILITY DOOR OPTIONS Hardened smoked glass door Expanded steel door Solid steel door A NEW METHOD OF THE GLUING We have put into action a fully automated line for glass and expanded steel gluing. We use the CNC system for the polyurethane glue application. This system has a three axes motion and the compound is applied evenly by a nozzle.
Free-Standing Cabinets
FREE-STANDING CABINETS – OVERVIEW RMA for maximum user’s comfort 17 RZA demountable 25 RDA with loading capacity 1 000 kg 31 RDE with IP 54 and with loading capacity 1 000 kg 37 RIE protection against harmful effect of water and dust (IP 54) 43 RPE, RPA for industrial environment 49 ROA with a rotating inner frame 53 RSX 19” open frames 57 00 16 0 00 11 1 00 00 1 01 11
11 1 RMA 10 1 10 0 0 00 01 0 10 10 1 00 11 1 10 0 01110000000111101 010 01 10 10 0 11 02 01 RMA Time-proven cabinet for data and telecommunication purposes 17
Detail of fixture of the cabinet removable rear cover Detail of the removable side panel lock HIGH RIGIDITY CONSTRUCTION RMA RMA has a robust welded construction. High quality processing and the newest technologies ensure a perfect look of the cabinet. FLEXIBLE DOOR OPENING The hinge system enables almost 180° wide opening of the door. The door can be easily removed and mounted for a change of the door opening direction.
CABINET REAR COVER Removable side and rear covers are secured with locks. Panels are operated by the same key like front door OPENING FOR A FAN UNIT RMA A large opening covered with a breakout-type blanking panel enables mounting and removal of the Triton fan unit from outside of the cabinet without a need of using screws.. BREAK-OUT BLANKING PANELS Entry openings for cables in the rear part of the cabinet are covered with breakout-type blanking panels.
HIGH RIGIDITY CONSTRUCTION RMA RMA has a robust welded construction. High quality processing and the newest technologies ensure a perfect look of the cabinet. FLEXIBLE DOOR OPENING The hinge system enables almost 180° wide opening of the door. The door can be easily removed and mounted for a change of the door opening direction. rma 800 x 1000 mm TRITON HANDLES For several years, Triton has been making its own handles for free-standing cabinets.
RMA rma 800 x 800 mm two-box rma 600 x 800 mm rma 800 x 800 mm rma 800 x 800 mm 21
RMA 600 x 600 Type A B 770 668 C D E Openings for fan* Weight gross (kg) Weight net (kg) 600 600 1 40.3 33.5 (mm) RMA RMA-15-A66–CAX–A1 487 RMA-18-A66–CAX–A1 900 798 487 600 600 1 44.1 37.3 RMA-22-A66–CAX–A1 1080 978 487 600 600 2 49.3 42.5 RMA-27-A66–CAX–A1 1300 1198 487 600 600 2 58.3 51.4 RMA-32-A66–CAX–A1 1525 1423 487 600 600 3 65.1 58.1 RMA-37-A66–CAX–A1 1750 1648 487 600 600 3 72.2 65.
RMA 800 x 800 Type A B 770 668 C D E Openings for fan* Weight gross (kg) Weight net (kg) 800 800 1 58.5 48.3 (mm) RMA-15-A88–CAX–A1 687 RMA-18-A88–CAX–A1 900 798 687 800 800 1 63.2 53.0 RMA-22-A88–CAX–A1 1080 978 687 800 800 2 69.6 59.3 RMA-27-A88–CAX–A1 1300 1198 687 800 800 2 80.3 69.9 RMA-32-A88–CAX–A1 1525 1423 687 800 800 3 88.6 78.2 RMA-37-A88–CAX–A1 1750 1648 687 800 800 3 97.2 86.6 1970 1868 687 800 800 3 105.4 94.
RMA FREE-STANDING CABINET DESCRIPTION, PURPOSE OF USE RMA • 19“ free-standing cabinet with IP 30 protection • Cabinet includes 4 sliding vertical rails for device mounting (6 rails for cabinets deeper than 800 mm). • Cabinet construction: – welded steel frame with removable side panels – door glass: safety hardened, thickness 4 mm • Max. permissible load of the door is 20 kg. • Min. thickness of the surface finish is 65 µm.
11 1 RZA 10 1 10 0 0 00 01 0 10 10 1 00 11 1 10 0 01110000000111101 010 01 10 10 0 11 01 01 RZA RZA combines the technical perfection of RMA with advantages of a demountable cabinet.
BREAKOUT-TYPE BLANKING PANELS Entry openings for cables in the rear part of the cabinet are covered with breakout-type blanking panels. To avoid dust penetration, it is possible to seal the cables at the entry opening by a brush strip (370 x 90 mm, supplied with the cabinet), eventually only by a plastic protective frame. A large opening in the top covered with a breakout-type blanking panel enables mounting and removal of a Triton fan unit from outside of the cabinet without a need of using screws.
DEMOUNTABILITY RZA Individual RZA parts are joined together by a system of screwed connections to a compact complex with the same maximal loading capacity as a welded cabinet. Most of the parts are joined by Tap-Tite technology thread-forming screws. This ensures a very high rigidity of a screwed connection even after a number of demounting. The product is supplied assembled and it is possible to be moved to difficult to reach places after partial or complete dismantling.
RZA 600 x 600 Type A B 770 668 C D E Openings for fan* Weight gross (kg) Weight net (kg) 600 600 1 42.5 35.7 (mm) RZA RZA-15-A66–CAX–A1 487 RzA-18-A66–CAX–A1 900 798 487 600 600 1 46.3 39.5 RzA-22-A66–CAX–A1 1080 978 487 600 600 2 51.5 44.6 RzA-27-A66–CAX–A1 1300 1198 487 600 600 2 59.8 52.8 RzA-32-A66–CAX–A1 1525 1423 487 600 600 3 66.6 59.6 RzA-37-A66–CAX–A1 1750 1648 487 600 600 3 73.7 66.
RZA 800 x 800 Type A B C 770 668 D E Openings for fan* Weight gross (kg) Weight net (kg) 800 800 1 60.2 50.0 (mm) RZA-15-A88–CAX–A1 687 RZA-18-A88–CAX–A1 900 798 687 800 800 1 64.9 54.7 RZA-22-A88–CAX–A1 1080 978 687 800 800 2 71.3 61.1 RZA-27-A88–CAX–A1 1300 1198 687 800 800 2 81.1 70.7 RZA-32-A88–CAX–A1 1525 1423 687 800 800 3 89.5 79.0 RZA-37-A88–CAX–A1 1750 1648 687 800 800 3 98.0 87.4 1970 1868 687 800 800 3 106.3 95.
RZA FREE-STANDING CABINET DESCRIPTION, PURPOSE OF USE RZA • 19“ free-standing cabinet with IP 30 protection • Cabinet includes 4 sliding vertical rails for device mounting (6 rails for cabinets deeper than 800 mm). • Cabinet construction: – welded steel frame with removable side panels – door glass: safety hardened, thickness 4 mm • Max. permissible load of the door is 20 kg. • Min. thickness of the surface finish is 65 µm.
11 1 RDA 10 1 10 0 0 00 01 0 10 10 1 00 11 1 10 0 01110000000111101 010 01 10 10 0 11 02 01 RdA New server cabinet with loading capacity 1 000 kg suitable for data centers NEW 31
CABINET WITH SIDE MODULE Side module can be ordered for RDA cabinet (RDA-xx-Xxx-CXX-X1-XXX). MAXIMUM LOAD 1 000 KG RDA Cabinet has strengthened construction and is made from sheet steel with double thickness than cabinets with standard maximum load. FLEXIBLE DOOR OPENING Hinge system enables opening at almost 180°. Door can be easily dismantled and fixed to opposite side. TRITON HANDLES Triton has been producing own handles for freestanding cabinets several years already.
NEW ACTIVE COOLING RDA Active cooling is solved by using of standard fan units. Its installation is variable and provide lots of combinations. Fans can be mounted on the special cabinet door too. DOOR Front and back door can be ordered in all standard designs – glass, perforated, solid steel, one-wing or double-wing. rDa 300 x 1000 mm BASE SIDE MODULE Base is an integral part of cabinet due high permissible load.
34 RdA
RDA – skeleton without doors and panels A B C D E (mm) Gross weight (kg) Maximum recommended load (kg) Nett weight (kg) RDA-37-X68-CXX-A1-XXX 1750 1648 487 600 800 72,8 64,5 RDA-42-X68-CXX-A1-XXX 1970 1868 487 600 800 79,3 69,6 RDA-45-X68-CXX-A1-XXX 2105 2003 487 600 800 81,3 71,5 RDA-37-X61-CXX-A1-XXX 1750 1648 487 600 1000 87,4 76,7 RDA-42-X61-CXX-A1-XXX 1970 1868 487 600 1000 92,9 82,1 RDA-45-X61-CXX-A1-XXX 2105 2003 487 600 1000 95,1 84,3 RDA-37-X
SERVER CABINET RDA DESCRIPTION, PURPOSE OF USE RdA • 19‘‘ free-standing cabinet with IP 30 protection • Cabinet includes 4 sliding vertical rails for device mounting (6 rails for cabinets deeper than 800 mm) • Cabinet construction: – welded steel frame with possibility to mount metal covers and side module – glass door: safety hardened, thickness 4 mml • Max. permissible load of the door is 20 kg. • Min. thickness of the surface finish is 65 µm.
11 1 RDE 10 1 10 0 0 00 01 0 10 10 1 00 11 1 10 0 01110000000111101 010 01 10 10 0 11 02 01 Rde New server cabinet with IP 54 and loading capacity 1 000 kg, suitable for data centers NEW 37
CABINET WITH SIDE MODULE For RDE cabinet can be ordered side module (RDE-xx-Cxx-BXX-X1). This side module is designed for installation of active cooling or for comfortable cable management. MAXIMUM LOAD 1 000 kg RDE Cabinet has strengthened construction and is made from sheet steel with double thickness than cabinets with standard maximum load. STRENGTHENED VERTICAL RAILS Vertical rails are made from thicker material and differ from standard type thanks to its shape as well.
NEW RDE PROTECTION AGAINS DUST AND HUMIDITY IP 54 All the doors and covers are equipped with a sealing that ensures protection against dust penetration and humidity. The protection is lowered to IP 30 in case of the cooling unit installation. SPECIAL DOOR FOR 19‘‘ CLIMATIZATION Special door with deflector, which ensures air circulating from the cooling unit. rDE 800 x 1000 mm BASE Base is an integral part of cabinet due high permissible load.
RdE Telescopic frame for side cooling unit EVE fastening Side cooling unit EVE suction slot Cooled air OUTPUT of side cooling unit EVE 40
Rde A B C 1970 1868 D E Gross weight (kg) Nett weight (kg) 600 800 127.0 118.7 (mm) RDE-42-A68-CCX-A1 687 RDE-45-A68-CCX-A1 2105 2003 687 600 800 132.8 124.4 RDE-42-A61-CCX-A1 1970 1868 687 600 1000 144.7 133.9 RDE-45-A61-CCX-A1 2105 2003 687 600 1000 151.1 140.3 RDE-42-A88-CCX-A1 1970 1868 687 800 800 157.0 147.4 RDE-45-A88-CCX-A1 2105 2003 687 800 800 163.7 154.0 RDE-42-A81-CCX-A1 1970 1868 687 800 1000 177.8 164.
SERVER CABINET RDE DESCRIPTION, PURPOSE OF USE RDE • 19‘‘ free-standing cabinet with IP 54 protection • Cabinet includes 4 sliding vertical rails for device mounting (6 rails for cabinets deeper than 800 mm) • Cabinet construction: – welded steel frame with removable side panels – glass door: safety hardened, thickness 4mm – doors with 3-point locking system are standard for this model • Max. permissible load of the door is 20 kg. • Min. thickness of the surface finish is 65 µm.
11 1 RIE 10 1 10 0 0 00 01 0 10 10 1 00 11 1 10 0 01110000000111101 010 01 10 10 0 11 01 01 RIE Data cabinets RIE with higher protection are designed to protect equipment especially against harmful effects of water and dust.
HIGHER PROTECTION Data cabinets RIE with a higher protection are designed to protect the equipment especially against harmful effects of water and dust. HIGH RIGIDITY CONSTRUCTION RIE RIE has a robust welded construction. High quality processing and the newest technologies ensure a perfect look of the cabinet. FLEXIBLE DOOR OPENING The hinge system enables almost 180° wide opening of the door. The door can be easily removed and mounted for a change of the door opening direction.
RIE CABLE INPUTS Cable access in the top and bottom part of the cabinet, dimension 300 x 100 mm, covered with blanking panel. CASTORS, NIVELATION FEET Preparation for mounting of castors, heavy-load castors and nivelation feet.
RIE TOP COOLING UNIT RIE cabinets are standardly prepared for installation of top cooling unit EHE. Once the cooling unit is mounted, the IP protection is lowered to IP 30. Cooling unit is supplied as an optional accessory. 19‘‘ INNER COOLING UNIT ERE It is necessary to mount a special door with deflector when using this cooling unit, which ensures air circulating from the air-conditioner. SIDE COOLING UNIT EVE It is mounted on the outer side of cabinet`s side panel.
Rie 600 x 600 Type A B C 1300 1176 D E Weight gross (kg) Weight net (kg) 600 600 66.8 59.9 (mm) RIE-27-A66-CCX-A1 487 RIE-32-A66-CCX-A1 1525 1401 487 600 600 73.8 66.9 RIE-37-A66-CCX-A1 1750 1626 487 600 600 82.0 75.0 RIE-42-A66-CCX-A1 1970 1846 487 600 600 89.6 82.5 A B C D E Weight gross (kg) Weight net (kg) 68.0 Maximal recommended load (kg) 400 RIE 600 x 800 (mm) RIE-27-A68-CCX-A1 1300 1176 487 600 800 76.
RIE FREE-STANDING CABINET DESCRIPTION, PURPOSE OF USE RIE • 19“ free-standing cabinet with IP 54 protection • Cabinet includes 4 sliding vertical rails for device mounting (6 rails for cabinets deeper than 800 mm). • Cabinet construction: – welded steel frame with removable side panels – door glass: safety hardened, thickness 4 mm – three-point lock is standard for this model • Max. permissible load of the door is 20 kg. • Min. thickness of the surface finish is 65 µm.
11 1 RPE, RPA 10 1 10 0 0 00 01 0 10 10 1 00 11 1 10 0 01110000000111101 010 01 10 10 0 11 01 01 RPE, RPA (Industrial cabinets) rpe – IP 54, rpa – IP 30 Cabinet for industrial environment intended for installation of computers or control components of technological units.
WE PRODUCE THE CABINET IN TWO MODIFICATIONS RPE with IP54 protection suitable especially for dusty environment. RPA with IP30 protection has a perforation in the base and top part including cable entries and preparations for fan units. RPE, RPA PROTECTION AGAINST DUST AND HUMIDITY The RPE cabinet is without a perforation, all the doors and covers are equipped with a sealing that ensures protection against dust penetration and humidity.
RPE. RPA A C D E (mm) Weight gross (kg) Maximal recommended load (kg) Weight net (kg) IP protection RPA-37-A66-CAX-A1 1750 487 600 600 75.6 68.5 400 30 RPE-37-A66-CAX-A1 1750 487 600 600 91.8 84.
FREE-STANDING CABINET RPE, RPA DESCRIPTION, PURPOSE OF USE RPE, RPA • 19“ free-standing cabinet with protection IP 54 (RPE), IP 30 (RPA) • Cabinet includes 4 sliding vertical rails for installing the device • Cabinet construction: – welded steel frame with removable side panels – door glass: safety hardened, thickness 4 mm • Max. permissible load of the door is 20 kg. • Min. thickness of the surface finish is 65 µm.
11 1 ROA 10 1 10 0 0 00 01 0 10 10 1 00 11 1 10 0 01110000000111101 010 01 10 10 0 11 01 01 ROA ROA is a unique in the field of data and communication cabinets.
The hinges enable 180° wide opening or easy door removal. Half-cylindrical type of this handle offering higher safety is also available. TWO BASIC CONTRUCTION INnOVATION ROA 1. rotating 19“ rack frame provides convenient access to all installed components 2. interesting styling of an octagonal shape. The rotating 19“ frame is a unique patented solution which allows mounting of common components in the 19“ frame and passing all cables through the top or bottom of the frame.
ROA 800 x 800 Type A B C D E (mm) Weight gross (kg) Weight net (kg) ROA-27-A88–CAX–A1 1628 1373 580 800 800 153.8 143.3 ROA-32-A88–CAX–A1 1850 1595 580 800 800 164.6 154.1 ROA-37-A88–CAX–A1 2072 1817 580 800 800 175.5 164.9 ROA-42-A88–CAX–A1 2294 2039 580 800 800 186.2 175.5 A B C D E Weight gross (kg) Weight net (kg) ROA-27-A99–CAX–A1 1628 1373 680 900 900 213.1 202.7 ROA-32-A99–CAX–A1 1850 1595 680 900 900 225.1 214.
ROA FREE-STANDING CABINET DESCRIPTION, PURPOSE OF USE ROA • 19“ free-standing cabinet with IP 30 protection • Cabinet construction: – welded steel frame with removable side panels – door glass: safety hardened, thickness 4 mm • Max. permissible load of the door is 20 kg. • Min. thickness of the surface finish is 65 µm. • These cabinets are intended for installation of data and telecommunication devices and their distribution systems.
11 1 RSX 10 1 10 0 0 00 01 0 10 10 1 00 11 1 10 0 01110000000111101 010 01 10 10 0 11 01 01 RSX Single section and double section 19“ open frames 57
SINGLE SECTION FRAMES RSX We recommend the single section open frames for simple installations without heavy components. rsx 600 x 600 mm HIGH RIGIDITY CONSTRUCTION Vertical profile rails provide a high maximal loading capacity and a rigidity of an open frame. rsx 600 x 700 mm 58 STABILIZATION SET DOUBLE SECTION FRAMES It is mounted additionally on the base of the double section frame and increases stability of the whole set in case of installation of slide-out devices, e.g. servers.
SINGLE SECTION 600 x 600 Type a B D e Weight gross (kg) mm Maximal recommended load (kg) Weight net (kg) RSX–27–XS6–CXX–A3 1365 616 600 34.3 27.5 RSX–32–XS6–CXX–A3 1587 616 600 36.4 29.6 RSX–37–XS6–CXX–A3 1809 616 600 38.4 31.7 RSX–42–XS6–CXX–A3 2031 616 600 40.5 33.7 RSX–45–XS6–CXX–A3 2165 616 600 41.7 35.0 D e Weight gross (kg) Weight net (kg) 150 DOUBLE SECTION 600 x 600 a B mm RSX–27–XD6–CXX–A3 1365 460 616 600 51.4 43.
RSX 19“ OPEN FRAMES DESCRIPTION, PURPOSE OF USE RSX • 19“ open frames are used for installations of devices in predetermined rooms. • 19“ open frames are produced single sectioned and double sectioned. • For better stability it is advisable to use a double section frame. • Frame construction: – demountable – steel parts – 19“ profile frame is suitable for placing directly on the floor using nivelation feet or castors (castors are not a part of the supply) • Min.
Data Centers NEW
DATA CENTERS – OVERVIEW Data centers 63 Examples of usage 64 00 62 0 00 11 1 00 00 1 01 11
DATA CENTERS DATA CENTERS Our company has launched RDA free-standing cabinet with loading capacity 1000 kg in its production programme. This product can be a basic element for data centers designing. We have prepared a few examples of our bigger realizations of data centers for an illustration, including also our sample data center TRITON, which was built up in our showroom and is at disposal for your visit after setting up the date and time with our sales department.
DATA CENTERS DATA CENTER – TRITON 64
DATA CENTERS DATA CENTER – REFERENCE INSTALLATIONS 65
DATA CENTERS DATA CENTER – REFERENCE INSTALLATIONS 66
Wall-Mounted Cabinets
WALL-MOUNTED CABINETS – OVERVIEW RBA – one-sectioned a classic for medium size installations 57 RBA – two-sectioned an easy access to the rear section 69 RUA with removable side panels 73 RXA „Flat-Pack“ conception 79 RBA – 10“ for smaller projects 83 00 68 0 00 11 1 00 00 1 01 11
00 11 11 00 01 01 1 RBA – one-sectioned 10 1 00 0 00 11 0 0 01 00 0 0 11 11 RBA 1 01 10 1 – one-sectioned The fully welded wall-mounted cabinet is a classic for medium size installations. It is well-proven by thousands of successful installations. High quality processing ensures an excellent look and a high utility value.
DOOR RBA – one-sectioned The cabinet has fully glass door in standard. It can be steel or perforated if required. HIGH RIGIDITY CONSTRUCTION Cabinet has a robust welded construction. High quality processing and the up-to-date technology ensure a perfect look of the cabinet. FLEXIBLE DOOR OPENING The hinge system enables almost 180° wide opening of the door. Doors can be easily removed. DOOR LOCK It enables an easy and quick access into the cabinet.
rba (DELTA B 4S) A B C D E R1 R2 Weight gross (kg) (mm) Weight net (kg) RBA-04-AS4–CAX–A1 280 175 516 600 395 234 420 12.7 12.4 RBA-06-AS4–CAX–A1 370 265 516 600 395 324 420 14.8 14.5 RBA-09-AS4–CAX–A1 500 395 516 600 395 454 420 17.8 17.4 RBA-12-AS4–CAX–A1 635 530 516 600 395 589 420 20.9 20.5 RBA-15-AS4–CAX–A1 770 665 516 600 395 724 420 24.0 23.6 RBA-18-AS4–CAX–A1 900 795 516 600 395 854 420 27.0 26.
WALL-MOUNTED CABINET RBA – one-sectioned DESCRIPTION, PURPOSE OF USE RBA – one-sectioned • 19“ one-sectioned wall-mounted cabinet with IP 30 protection • Cabinet is to be hanged right on the wall. • Cabinet includes two sliding vertical rails. • Cabinet construction: – compact welded cabinet – glass door: safety hardened glass, thickness 5 mm • Max. permissible load of the door is 10 kg. • Min. thickness of the surface finish is 65 µm.
00 11 11 00 01 01 1 RBA – two-sectioned 10 1 00 0 00 11 0 0 01 00 0 0 11 11 RBA 1 01 10 1 – two-sectioned The data and telecommunication cabinet is a very successful version of twosectioned cabinets. Opening parts of the cabinet enable an easy access to the rear cabinet section.
DOOR RBA – two-sectioned The cabinet has fully glass door in standard. It can be steel or perforated if required. HIGH RIGIDITY CONSTRUCTION Cabinet has a robust welded construction. High quality processing and the up-to-date technology ensure a perfect look of the cabinet. FLEXIBLE DOOR OPENING The hinge system enables almost 180° wide opening of the door. The door can be easily removed. LOCKS Door lock and back section have the same key.
rba (DELTA B 2d) Type A B C D E R1 R2 (mm) Weight gross (kg) Weight net (kg) Maximal recommended load (kg) 280 175 516 600 295 234 420 11.9 11.6 20.0 370 265 516 600 295 324 420 13.7 13.4 25.0 RBA-09-AD2–CAX–A1 500 395 516 600 295 454 420 16.8 16.5 30.
DOOR RBA – two-sectioned The cabinet has fully glass door in standard. It can be steel or perforated if required. HIGH RIGIDITY CONSTRUCTION Cabinet has a robust welded construction. High quality processing and the up-to-date technology ensure a perfect look of the cabinet. FLEXIBLE DOOR OPENING The hinge system enables almost 180° wide opening of the door. The door can be easily removed. LOCKS Door lock and back section have the same key.
rba (DELTA B 5d) A B C D E R1 R2 Weight gross (kg) (mm) Weight net (kg) Maximal recommended load (kg) RBA-04-AD5–CAX–A1 280 175 516 600 515 234 420 16.2 15.9 20.0 RBA-06-AD5–CAX–A1 370 265 516 600 515 324 420 18.3 17.9 20.0 RBA-09-AD5–CAX–A1 500 395 516 600 515 454 420 21.7 21.4 25.0 RBA-12-AD5–CAX–A1 635 530 516 600 515 589 420 25.4 25.1 25.0 RBA-15-AD5–CAX–A1 770 665 516 600 515 724 420 29.1 28.7 30.
RBA WALL-MOUNTED CABINET – two-sectioned DESCRIPTION, PURPOSE OF USE RBA – two-sectioned • 19“ two-sectioned wall-mounted cabinet with IP 30 protection • Cabinet is to be hanged right on the wall. • Cabinet includes two sliding vertical rails. • Cabinet construction: – compact welded cabinet – glass door: safety hardened glass, thickness 5 mm • Max. permissible load of the door is 10 kg. • Min. thickness of the surface finish is 65 µm.
00 11 11 00 01 01 1 RuA 10 1 00 0 00 11 0 0 01 00 0 0 11 11 1 01 10 1 RuA RUA wall-mounted cabinet is one of the one-sectioned wall-mounted cabinets. Thanks to removable side panels, installed devices are very easily accessible.
DOOR The cabinet has fully glass door in standard. It can be steel or perforated if required. HIGH RIGIDITY CONSTRUCTION RuA Cabinet has a robust welded construction. High quality processing and the up-to-date technology ensure a perfect look of the cabinet and maximal loading capacity of 30 kg. FLEXIBLE DOOR OPENING The hinge system enables almost 180° wide opening of the door. Doors can be easily removed. DOOR LOCK It enables an easy and quick access into the cabinet.
rua (DELTA U AS4) TYPE A B C D E R1 R2 (mm) Weight gross (kg) Weight net (kg) RuA-06-AS4–CAX–A1 370 265 490 600 395 324 420 15.4 15.1 RuA-09-AS4–CAX–A1 500 395 490 600 395 454 420 18.5 18.2 RuA-12-AS4–CAX–A1 635 530 490 600 395 589 420 21.7 21.3 RuA-15-AS4–CAX–A1 770 665 490 600 395 724 420 24.1 23.8 RuA-18-AS4–CAX–A1 900 795 490 600 395 854 420 27.2 26.
RUA WALL-MOUNTED CABINET DESCRIPTION, PURPOSE OF USE RuA • 19“ one-sectioned wall-mounted cabinet with IP 30 protection • Removable side panels are locked with locks. • Cabinet is to be hanged right on the wall. • Cabinet includes two sliding vertical rails. • Cabinet construction: – welded frame with removable side panels secured by locks – glass door: safety hardened glass, thickness 5 mm • Max. permissible load of the door is 10 kg. • Min. thickness of the surface finish is 65 µm.
00 11 11 00 01 01 1 RxA 10 1 00 0 00 11 0 0 01 00 0 0 11 11 1 01 10 1 RxA RXA wall-mounted cabinet represents the conception of „flat pack“, which means a demountable cabinet that is supplied disassembled.
DOOR These cabinets are supplied only with a glass door with a lock. FLAT-PACK`S CONCEPTION RxA Reduces cost of transportation and storage. Together with a unique construction, it contributes to the attractive price while keeping all functional characteristics. FLEXIBLE DOOR OPENING The hinge system enables a comfortable access. DOOR LOCK Locks safely the cabinet and protects the installed devices.
rXa (DELTA X AS4) Type A B C D E R1 R2 Weight gross (kg) (mm) Weight net (kg) 230 180 505 550 400 180 435 11.2 11.0 320 270 505 550 400 270 435 13.3 13.0 RXA-09-AS4–CAX–A1 463 412 505 550 400 412 435 15.4 15.1 RXA-12-AS4–CAX–A1 580 530 505 550 400 530 435 18.7 18.
RXA WALL-MOUNTED CABINET DESCRIPTION, PURPOSE OF USE RxA • Demountable 19“ wall mounted cabinet with IP 30 protection, supplied disassembled • Cabinet is to be hanged right on the wall. • Cabinet includes two adjustable vertical rails. • Cabinet construction: – cabinet is made from parts joined by plastic pins – glass door: safety hardened glass, thickness 5 mm • Max. permissible load of the door is 10 kg. • Min. thickness of the surface finish is 65 µm.
00 11 11 00 01 01 1 RBA – 10“ 10 1 00 0 00 11 0 0 01 00 0 0 11 11 RBA 1 01 10 1 – 10“ The cabinet is often used for the realization of small projects such as home networks or small company networks (SOHO).
DOOR The cabinet has fully glass door in standard. It can be steel or perforated if required. RBA – 10“ HIGH RIGIDITY CONSTRUCTION Cabinet has a robust welded construction. High quality processing and the up-to-date technology ensure a perfect look of the cabinet. FLEXIBLE DOOR OPENING The hinge system enables a comfortable access. DOOR LOCK Locks safely the cabinet and protects the installed devices.
rba (DELTA 10“) Type A B C D E R1 R2 Weight gross (kg) (mm) Weight net (kg) 248 169 255 310 260 212 212 5.5 5.4 337 258 255 310 260 301 212 6.9 6.9 RBA-09-AS3–CAX–C1 470 391 255 310 260 434 212 8.3 8.2 20 RBA – 10“ RBA-04-AS3–CAX–C1 RBA-06-AS3–CAX–C1 Maximal recommended load (kg) E D 40 THE USE OF THE CABINET 20 0 B A Ideal solution for installation of 10“ components.
RBA – 10“ WALL-MOUNTED CABINET DESCRIPTION, PURPOSE OF USE RBA – 10“ • 10“ wall-mounted cabinet with IP 30 protection • Cabinet is to be hanged right on the wall. • Cabinet includes two adjustable vertical rails. • Cabinet construction: – compact welded cabinet – glass door: safety hardened glass, thickness 5 mm • Max. permissible load of the door is 10 kg. • Min. thickness of the surface finish is 65 µm.
Special Cabinets
SPECIAL CABINETS – OVERVIEW BGX ceiling cabinet 93 RCA cabinet under the work desk 97 RFA cabinet divided into three-sections 101 00 92 0 00 11 1 00 00 1 01 11
00 11 11 00 01 01 1 bgx 10 10 00 0 00 1 0 10 10 0 01 1 1 01 0 10 10 bgx BGX is a special cabinet for mounting into standard and non-standard ceilings.
bgx MOUNTING INTO CEILINGS Its‘ dimensions enable mounting into standard (600 x 600 mm) and non-standard ceilings thanks to bedded frame edges. That enables to move the soffit panel or the plaster board over the box frame with no harm to the ceiling design. BEST PLACING The best placing is to 600 x 600 mm basic grid where it can replace the whole soffit panel.
bGX Type Weight net (kg) Maximal recommended load (kg) 11.6 11.
BGX CEILING CABINET DESCRIPTION, PURPOSE OF USE bgx • 19“ special cabinet to soffit with IP 30 protection • Cabinet is to be hanged into a soffit. • Welded frame with a pop-up frame with a span of 19“ • Cabinet construction: – compact welded cabinet • Min. thickness of the surface finish is 65 µm. • Cabinets are intended for installation of data and telecommunication devices and their distribution systems.
00 11 11 00 01 01 1 RcA 10 10 00 0 00 1 0 10 10 0 01 1 1 01 0 10 10 RcA RCA represents one of the non-standard data cabinet solutions. Its` construction is right from the beginning designed to concentrate an office network infrastructure under one of the office tables.
DOOR The cabinet has fully glass door in standard. It can be steel or perforated if required. HIGH RIGIDITY CONSTRUCTION Rca Cabinet has a robust welded construction. High quality processing and the up-to-date technology ensure a perfect look of the cabinet. FLEXIBLE DOOR OPENING The hinge system enables almost 180° wide opening of the door. Doors can be easily removed. DOOR LOCK It enables an easy and quick access into the cabinet.
rca (DELTA C) Type A B C D E (mm) Weight gross (kg) Weight net (kg) 620 515 490 600 800 48.0 40.1 620 515 490 600 900 53.2 43.4 RCA-12-A61-CAX-A1 620 515 490 600 1000 56.3 45.9 D E D A A E 200 RcA RCA-12-A68-CAX-A1 RCA-12-A69-CAX-A1 Maximal recommended load (kg) 38 70 B 1 90 70 0 3 70 20 B 1 90 37 20 03 8 0 C C CASTORS This type of cabinet is installed on castors (included in the supply). Two of them are with a brake.
RCA CONTAINER CABINET DESCRIPTION, PURPOSE OF USE RcA • 19“ container cabinet with IP 30 protection • Cabinet is intended to be placed on castors under a work desk. • The cabinet includes two pairs of vertical rails (three pairs at cabinets deeper than 800 mm). • Cabinet construction: – compact welded cabinet – glass door: safety hardened glass, thickness 5 mm • Max. permissible load of the door is 10 kg. • Min. thickness of the surface finish is 65 µm.
00 11 11 00 01 01 1 RfA 10 10 00 0 00 1 0 10 10 0 01 1 1 01 0 10 11 1 12 RFA RFA – solution for small and middle firms NEW
three sections New wall-mounted cabinet RFA is designed to meet requests of small and middle firms. The cabinet is divided into three sections. HIGH RIGIDITY CONSTRUCTION RfA Cabinet has a robust welded construction. High quality processing and the up-to-date technology ensure a perfect look of the cabinet.. NEW FLEXIBLE DOOR OPENING The hinge system enables almost 180° wide opening of the door. DOOR LOCK It enables an easy and quick access into the cabinet.
rfa Type Weight gross (kg) Weight net (kg) Maximal recommended load (kg) 27,3 26,9 50 RFA-12-A94-CAX-A1 1. section RfA 19“ equipment with max. height of 6U and depth of 230 mm can be installed into the first section. The equipment is placed vertically and 19“ rails can be adjusted in predefined positions. Power distribution panel 230V, supply adapters for active components or eventually data incoming lines, are typical devices installed in this section. 2.
rFa WALL-MOUNTED CABINET DESCRIPTION, PURPOSE OF USE RfA • 19“ one-sectioned wall-mounted cabinet with IP 30 protection • Three separate 19‘‘ sections • Cabinet is to be hanged right on the wall.. • Cabinet includes two adjustable sliding vertical rails in each section. • Cabinet construction: – welded frame – glass door: safety hardened glass, thickness 5 mm – metal door • Max. permissible load of the door is 10 kg. • Min. thickness of the surface finish is 65 µm.
Accessories
ACCESSORIES – OVERVIEW ACTIVE COOLING 107 CABLE ORGANIZATION SYSTEMS 115 OTHER ACCESSORIES 121 00 106 0 00 11 1 00 00 1 01 11
11 1 Active cooling 10 0 10 00 0 00 1 0 10 10 0 01 1 1 01 10 Active cooling Fan units, cooling units with static evaporator
Active cooling Active cooling RAC-DV-Axx-X1 RAC-DV-A02-X1 Into our offer, we newly include a special sheet-metal door with a preparation for the installation of the RAxCH-xxx-X3 ventilation units (two, four or six fans in the ventilating unit) designated for the most of the TRITON free standing cabinets. Each ventilation unit has its own separate thermostat which enables a better regulation of the excess heat dissipation.
Active cooling Active cooling 109
Active cooling Active cooling We are offering STULZ Cosmotec cooling units for active temperature control in our cabinets. EVE and EHE cooling units are designed for the cooling of server cabinets series RDE and RIE (with IP54 protection). They are suitable for operating in the offices and in industrial environment as well.
Active cooling RAB-KL-EVE-Xx, RAC-KL-EVE-Xx Side cooling unit EVE Suitable for mounting into the side module of the server cabinet.
Active cooling RAB-KL-ERE-A1, RAC-KL-ERE-A1 19‘‘ inner cooling unit ERE Active cooling NEW RAC-KL-ERE-A1 19” inner cooling unit ERE Part number RAC-KL-ERE-A1 112 Coolant Cooling capacity (W) type R134a 950 External dimensions Temperature range set up Power supply (V/Hz) Air flow (m3/h) Electric input (W) Noise level (dB) Weight (kg) 311 x 482,6 x 579,5 mechanical thermostat 230/50-60 575 620 65 36
RAC-CH-X05-X3 Active cooling STANDARD FAN UNITS RAB-CH-X01-A1 RAb-CH-X01-A1, RAC-CH-X01-A1 19“ horizontal fan unit, 2 fans, 2U, 220 V / 30 W, a thermostat SUPPLY Screw M6 x 10........................................................ 4x Plastic washer......................................................... 4x Captive nut M6....................................................... 4x RAB-CH-X04-X3 RAB-CH-Xxx-xx, RAC-CH-Xxx-xx These fan units are made especially for free-standing cabinets.
Active cooling STANDARD FAN UNITS RAX-CH-X01-X9 RAX-CH-X02-X9 RAX-CH-X01–X9 RAX-CH-X02-X9 Thermostat – adjustable switching temperature range from 0 °C up to +60 °C Plastic frame 120 x 120 mm with a filter RAX-CH-X03-X9 RAX-CH-X06-X9 RAX-CH-X03-X9 RAX-CH-X06-X9 Metal frame 120 x 120 mm without a filter Fan – 230 V / 15 W, 50 Hz / 0.09 A, 160 m3/h, 120 x 120 mm RAX-CH-X07-X9 114 RAX-CH-XXX-X1 RAX-CH-X07-X9 RAB-CH-XXX-X1, RAC-CH-XXX-X1 Fan unit for RFA, RUA cabinet 230 V, 50 Hz, 0.
11 1 CABLE ORGANIZATION SYSTEMS 10 0 10 00 0 00 1 0 10 10 0 01 1 1 01 10 CABLE ORGANIZATION SYSTEMS Complex organization system for optical and metallic data cables NEW
CABLE ORGANIZATION SYSTEMS CABLE ORGANIZATION SYSTEMS NEW RAC-MS-X21-X1 RAB-MS-X01-X1 RAB-MS-X21-X1, RAC-MS-X21-X1 RAB-MS-X01-X1 Big plastic transfer ring – management ring for cables with inner diameter 60 x 30 mm, designed for installation into steel parts with square-shaped opening 9 x 9 mm Sliding plastic cable guide MP319 (double transfer ring ‘fork’) – for optics cable management For mounting on C-profile RAX-CP-Xxx-X1 only.
NEW CABLE ORGANIZATION SYSTEMS CABLE ORGANIZATION SYSTEMS NEW RAX-CP-Xxx-X1 RAC-SM-Xxx-X1 RAX-CP-Xxx-X1 RAB-SM-Xxx-X1, RAC-SM-Xxx-X1 C alu-profile for cable management components – clamping of the plastic components by pressing into the profile only Connecting module RSX – Designed for connecting two RSX open frames with a possibility of cable management. It can be used as a side module as well.
CABLE ORGANIZATION SYSTEMS CABLE ORGANIZATION SYSTEMS RAB-VP-X02-A1 RAB-VP-X02-A1, RAC-VP-X02-A1 RAB-VP-X03-A1, RAC-VP-X03-A1 19“ 1U panel with cable trunking, one side plastic rail 19“ 1U panel with cable trunking, two-sided plastic rail SUPPLY Screw M6 x 10........................................................ 4x Plastic washer......................................................... 4x Captive nut M6....................................................... 4x SUPPLY Screw M6 x 10.................
RAB-VP-X16-A1 CABLE ORGANIZATION SYSTEMS CABLE ORGANIZATION SYSTEMS RAX-VP-Xxx-X2 RAb-VP-X16-A1, RAC-VP-X16-A1 RAX-VP-Xxx-X2 19“ cable management panel 1U, 5 x big click-in ring,oval holes Vertical cable canal 14-45U for RMA and RZA of 800 mm width. SUPPLY Screw M6 x 10........................................................ 4x Plastic washer......................................................... 4x Captive nut M6.......................................................
CABLE ORGANIZATION SYSTEMS CABLE ORGANIZATION SYSTEMS B A RAX-D1-X88-X3 RAX-D1-X48-X3 RAX-D1-Xxx-X3 Steel cable management rings type D1 SUPPLY Screw M6 x 10........................................................ 2x Plastic washer......................................................... 2x Captive nut M6.......................................................
11 1 Accessories 10 0 10 00 0 00 1 0 10 10 0 01 1 1 01 10 OTHER ACCESSORIES Accessories
Accessories FIBRE OPTIC RAB-F0-X57-A1 RAB-F0-X60-A1 RAb-FO-X57-A1, RAC-FO-X57-A1 RAb-FO-X60-A1, RAC-FO-X60-A1 19‘‘ Fixed FO panel 1U 19‘‘ Fixed FO panel 2U SUPPLY Screw M6 x 10........................................................ 4x Plastic washer......................................................... 4x Captive nut M6....................................................... 4x SUPPLY Screw M6 x 10........................................................ 4x Plastic washer.........................
RAB-F0-X61-A1 Accessories FIBRE OPTIC RAC-F0-X62-A1 RAB-FO-X61-A1, RAC-FO-X61-A1 RAB-FO-X62-A1, RAC-FO-X62-A1 19‘‘ Front plate 2U 48 ST 19‘‘ Front plate 2U 48 SC SUPPLY Screw M4 x 6.......................................................... 4x SUPPLY Screw M4 x 6.......................................................... 2x RAB-F0-X63-A1 RAb-FO-X63-A1, RAC-FO-X63-A1 19‘‘ Front plate 1U 24 SC DUPLEX SUPPLY Screw M4 x 6..........................................................
Accessories FIBRE OPTIC, SHELVES FTK-X01-H1 RAB-UP-X09-A1 ftk-X01-H1 RAb-UP-X09-A1, RAC-UP-X09-A1 Splice cassette with a cover 19“ Drop-down shelf for keyboard, maximal loading capacity 15 kg SUPPLY Screw M6 x 10........................................................ 4x Plastic washer......................................................... 4x Captive nut M6.......................................................
RAB-UP-550-A1 RAC-UP-350-A3 RAb-UP-xxx-A1, RAC-UP-xxx-A1 RAB-UP-xxx-A3, RAc-UP-xxx-A3 19“ Shelf with perforation 1U 19“ Shelf with perforation 1U Type Depth (mm) Maximal loading capacity (kg) RAx-UP-150-A1 RAx-UP-250-A1 RAx-UP-350-A1 RAx-UP-450-A1 RAx-UP-550-A1 RAx-UP-650-A1 RAx-UP-750-A1 RAx-UP-850-A1 RAx-UP-850-A1 150 250 350 450 550 650 750 850 950 15 20 40 40 40 40 40 40 40 SUPPLY Screw M6 x 10.......... (dimensions 150 and 250 mm – 4x). 8x Plastic washer...........
Accessories BASES, FILTERS RAC-PO-X88-XN RAb-PO-Xxx-XN, RAC-PO-Xxx-XN The base is fully universal, this means that it is usable for all types of free-standing racks except ROA, RDA, RDE and RSX. The construction of the base is formed of two side profiles which correspond to the depth of the cabinet, and two cover panels (front and back) with a corresponding width.
MOUNTING ANGLES, CASTORS, FEET, STABILIZERS A 88 RAB-NL-X01-X1 RAX-MS-X82-X1 RAb-NL-Xxx-X1, RAC-NL-Xxx-X1 RAX-MS-X82-X1 Pair of mounting angles Heavy duty castors with maximal loading capacity of 4 castors 800 kg. Type A (mm) RAx-NL-X01-X1 RAx-NL-X02-X1 RAx-NL-X03-X1 RAx-NL-X04-X1 380 580 680 780 set Castors with a brake................................... 2x Castors without a brake.............................. 2x Screw m5 x 12 Thorx................................ 16x Enlarged washer 5,5......
Accessories BLANKING PANELS, CABLE ENTRY PANELS RAB-ZP-X03-A1 RAb-ZP-X03-A1, RAC-ZP-X03-A1 RAb-ZP-X03-A2, RAC-ZP-X03-A2 19’’ 1U Cable entry panel 19’’ 1U Cable entry panel with brush strip SUPPLY Screw M6 x 10........................................................ 4x Plastic washer......................................................... 4x Captive nut M6....................................................... 4x SUPPLY Screw M6 x 10........................................................
RAX-MS-X15-X1 RAX-MS-X18-X1, RAX-MS-X17-X1 RAX-mS-X15-X1, RAX-mS-X16-X1 RAX-mS-X17-X1, RAX-mS-X18-X1 RAX-mS-X15-X1 – blanking panel with a brush, 370 x 90 mm RAX-mS-X17-X1 – plastic frame for a breakout-type blanking panel 300 x 70 mm RAX-mS-X18-X1 – plastic frame for a breakout-type blanking panel 370 x 90 mm RAX-mS-X16-X1 – blanking panel with a brush, 300 x 70 mm Accessories CABLE ORGANISERS Openings with breakout-type blanking panels fixed with several bonds are intended for cables entering int
POWER DISTRIBUTION 230 V – OVERVIEW 1U 19“ 1U 8x 2m 3 x 1,5 mm CZ-DE Universal RAB-PD-X03-A1 1U 19“ 1U 8x 2m 3 x 1,5 mm CZ-DE Universal RAB-PD-X05-A1 1U 19“ 1U 8x 2m 3 x 1,5 mm CZ-DE Universal RAB-PD-X07-A1 1U 19“ 1U 8x 2m 3 x 1,5 mm CZ-DE Universal RAB-PD-X11-A1 1U 19“ 1U 7x 2m 3 x 1,5 mm CZ-DE Universal RAB-PD-X02-A1 1U 19“ 1U 8x 2m 3 x 1,5 mm CZ-DE Universal RAB-PD-X04-A1 1U 19“ 1U 8x 2m 3 x 1,5 mm CZ-DE Universal RAB-PD-X06-A1 1U 19“ 1U 8x 2m 3 x 1,5 mm CZ-
POWER DISTRIBUTION 230 V NEW RAB-PD-X01-A1 Accessories NEW RAB-PD-X02-A1 RAB-PD-X01-A1 RAB-PD-X02-A1 19‘‘ distribution panel 1U, 8 sockets ČSN standard, max. 16 A, cable 3 x 1.5 mm x 2 m long, DIN49441 16 A plug, RAL 9005 19‘‘ distribution panel 1U, 8 sockets DIN standard, max. 16 A, cable 3 x 1.5 mm x 2 m long, DIN49441 16 A plug, RAL 9005 SUPPLY Screw M6 x 16 with washer . ................................. 2x Captive nut M6.......................................................
POWER DISTRIBUTION 230 V Accessories NEW NEW RAB-PD-X07-A1 RAB-PD-X08-A1 RAB-PD-X07-A1 RAB-PD-X08-A1 19‘‘ distribution panel 1U, 8 sockets ČSN standard, max. 16 A, cable 3 x 1.5 mm x 2 m long, DIN49441 16 A plug, Varistor surge protection, RAL 9005 19‘‘ distribution panel 1U, 8 sockets DIN standard, max. 16 A, cable 3 x 1.5 mm x 2 m long, DIN49441 16 A plug, Varistor surge protection, RAL 9005 SUPPLY Screw M6 x 16 with washer . ................................. 2x Captive nut M6...................
POWER DISTRIBUTION 230 V NEW RAB-PD-X51-X1 RAB-PD-X52-X1 RAB-PD-X51-X1 RAB-PD-X52-X1 Vertical distribution panel, 24 sockets ČSN standard, max. 16 A, cable 3 x 1.5 mm x 2 m long, IEC60309 plug, surge protection, Varistor surge protection, RAL 9005 Vertical distribution panel, 20 sockets IEC320 C13, 4 sockets IEC320 C 19. 2 x 16 A master air circuit breaker, max. 32 A, cable 3 x 6.0 mm x 3 m long, IEC60309 plug, RAL 9005 SUPPLY Screw M6 x 16 with washer . .................................
Accessories LIGHTING UNIT NEW NEW RAX-OJ-X03-X1 RAX-OJ-X04-X1 RAX-OJ-X03-X1 RAX-OJ-X04-X1 LED-diode lighting unit with magnet. The lighting unit can be mounted in 19‘‘ metal cover (RAC-OP-X01-A1). Cable for LED-diode lighting unit, DIN and ČSN norm, length 2 m. LED-diode lighting unit with magnet. The lighting unit can be mounted in 19‘‘ metal cover (RAC-OP-X01-A1). Cable for LED-diode lighting unit, IEC norm, length 2m.
RAX-ZL-X15-X1 RAX-SV-X01-X1 RAX-ZL-Xxx-X1 RAX-sv-X01-X1 Earthing rail Earthing clamp Type Height (U) Height (mm) RAX-ZL-X15-X1 15 667 RAX-ZL-X18-X1 18 800 RAX-ZL-X22-X1 22 978 RAX-ZL-X27-X1 27 1200 RAX-ZL-X32-X1 32 1422 RAX-ZL-X37-X1 37 1645 RAX-ZL-X42-X1 42 1867 RAX-ZL-X45-X1 45 2000 Accessories EARTHING, MOUNTING PACKETS SUPPLY Screw M5 x 18 Thorx............................................... 2x Enlarged washer.....................................................
Accessories 10“ Accessories RAB-PP-X01-C1 RAC-UP-X01-C1 RAb-PP-X01-C1, RAC-PP-X01-C1 RAB-UP-X01-C1, RAc-UP-X01-C1 10“ modular patch panel for max. 8 keystone modules 10” shelf SUPPLY Screw M6 x 10........................................................ 4x Plastic washer......................................................... 4x Captive nut M6....................................................... 4x SUPPLY Screw M6 x 10........................................................ 4x Plastic washer.....
RAX-MS-X07-X1 Accessories LOCKS RAX-MS-X08-X1 RAX-mS-X07-X1 RAX-mS-X08-X1 Key lock for wall-mounted rack, identical key Plastic swinghandle TRITÓN with cam-lock insert, standard for free-standing cabinets, identical key RAX-mS-X65-X1 – Plastic swinghandle TRITÓN with half-cylinder insert, offers higher safety and strength, various key PATENT: PUV 2009-22086 RAX-MS-X09-X1 RAX-MS-X10-X1 RAX-mS-X09-X1 RAX-mS-X10-X1 Key lock for side panels of free-standing racks Standard keys for the front doors o
Accessories DOOR HINGES RAX-MS-X12-X1 RAX-MS-X13-X1 RAx-MS-X12-x1 RAx-MS-X13-x1 Door hinge for wall-mounted fibre optic boxes Door hinge for free-standing and wall-mounted cabinets. Max. loading capacity of 1 pc is 15 kg SUPPLY Screw M5 x 12........................................................ 2x Nut M5...................................................................
PACKING, TRANSPORTATION Packing We deliver our products in new packing. We have fully replaced packing into polystyrene and bubble foil. Edges are shielded by a highly resistant polyurethane foam and the whole cabinet or clothes locker is protected with shrinkwrap against dust and scratching during transportation. Free standing cabinets and clothes lockers are distributed on wooden pallets. Transportation The transportation is provided via our contract carriers.
TECHNICAL SUPPORT 1.Clear span between vertical rails 19“ system 10“ system 2. Vertical rail 3.
4. Maximal available depths in free-standing and wall-mounted cabinets Free-standing cabinets 800 x 600 – 575 mm 800 x 800 – 775 mm 800 x 900 – 875 mm 800 x 1000 – 975 mm 600 x 600 600 x 800 600 x 900 600 x 1000 – 575 mm – 775 mm – 875 mm – 975 mm Wall-mounted cabinets AS4 – 360 mm AS5 – 460 mm AS6 – 560 mm AD2 – 260 mm AD5 – 480 mm AD6 – 580 mm 5. Spacing between the front vertical rail and the door glass at the maximal span 600 x 800 x – 35 mm – 50 mm 6.
CERTIFICATION 142
00 00 1 01 00 0 10 01 1 10 10 143
CERTIFICATION 144
00 00 1 01 00 0 10 01 1 10 10 145
CERTIFICATION 146
0 00 00 0 11 01 0 00 11 1 01 0 147
CERTIFICATION 148
0 00 00 0 11 01 0 00 11 1 01 0 149
CERTIFICATION 150
00 00 1 01 00 0 10 01 1 10 10 151
CERTIFICATION 152
NOTES 153
SYSTEM OF PART NUMBERS Orientation part numbering of free-standing cabinets FRONT DOOR LOCK Type D – maximum load 1000 kg I – RIE M – RMA O – ROA P – RPA, RPE S – 19“ open cabinet Z – RZA – demountable Height WIDTH DEPTH height of cabinet or rack in units 6 – 600 mm 8 – 800 mm 6 – 600 mm 8 – 800 mm 9 – 900 mm 1 – 1000 mm 2 – 1200 mm A – Triton plastic handle C – three-point lock E – three-point lock on Triton handle with cylindrical inset F – Triton handle with cylindrical inset P – Triton handle w
Part numbers for wall-mounted and special cabinets Type B – RBA – glass door C – RCA – under the table F – RFA – three sections U – RUA – glass door with removable side covers G – BGX – ceiling X – RXA – Flat Pack Height NUMBER OF SECTIONS DEPTH LOCK ENCLOSURE height of cabinet or rack in units S – one-sectioned D – two-sectioned 2, 3, 4, 5, 6 (approximate depth in decimetres) A – with lock X – with no lock A – 19“ C – 10“ X – without inch spacing R X X–X X–X X X–X X X–X 1 ENCLOSURE IP Protecti
Map Dresden Chemnitz Praha Pardubice Plzeň Brno Tritón Pardubice, spol. s r. o. Starý Mateřov 130, 530 02 Pardubice 2, Czech Republic GPS: 50°0‘4.624“N, 15°43‘28.292“E Tel.: +420 467 401 111 Fax: +420 467 401 130 E-mail: sale@triton.cz www.triton.cz www.clotheslockers.eu Tritón Pardubice, spol. s r. o. branch office Praha Klánovická 485/43, 198 02 Praha 9, Czech Republic GPS: 50°6‘19.701“N, 14°32‘36.692“E Tel.: +420 242 441 160 Fax: +420 242 441 164 E-mail: praha@triton.cz www.triton.
Tritón Pardubice, spol. s r. o. Starý Mateřov 130, 530 02 Pardubice, Czech Republic Tel.: +420 467 401 111, Fax: +420 467 401 130 E-mail: sale@triton.cz www.triton.cz www.clotheslockers.eu Triton Chemnitz GmbH Wolgograder Allee 24, 09123 Chemnitz, Germany Tel.: +49 371 5202271, +49 371 2621192 Fax: +49 371 5202272 E-mail: info@triton-racks.de www.triton-racks.de www.garderobenspinde.