User Manual

49
REINSTATE USER
(Manager feature only)
- Always perform this operation with the door(s) open!
1. Enter Manager Code and HOLD DOWN LAST DIGIT OF CODE until the lock signals with two (2) sets
of double beeps.
2. PRESS 1. Lock signals once. User is now reinstated.
3. If a mistake is made, wait thirty (30) seconds and repeat steps 1 and 2.
REMOVE USER
(Manager feature only)
- Always perform this operation with the door(s) open!
1. Enter Manager Code and HOLD DOWN LAST DIGIT OF CODE until the lock signals with two (2) sets
of double beeps.
2. PRESS 3. Lock signals once. User is now permanently removed.
3. If a mistake is made, wait thirty (30) seconds and repeat steps 1 and 2.
DUAL CODE OPERATION
(if feature is programmed)
- Always perform this operation with the door(s) open!
1. Must add second user to open lock (See ADD USER).
Second user CAN NOT be Disabled or Removed.
2. After first code is entered, second code must be entered within ten (10) seconds.
3. If Time Delay feature is also programmed, one valid code will start Delay period.
Both codes required to open lock in Open period.
SILENT SIGNAL A LARM
(if feature is programmed AND optional Alarm Box is connected to an alarm system)
- Always perform this operation with the door(s) open!
1. Enter last digit of code one (1) number higher or one (1) number lower.
Example: Code: 1-2-3-4-5-6
Duress: 1-2-3-4-5-5 or 1-2-3-4-5-7
2. The lock will open without any indication that the duress signal has been sent.
FT7000
XP