User Manual
34
FT7000
XP
- SITE PREPARATION AND INSTALLATION GUIDE
REMOVE / INSTALL NMD-100 DISPENSER
The NMD-100 dispensing mechanism is shipped inside the security vault (see section in this manual under
“COMBINATION LOCK” for opening lock mechanism). Follow the procedures below for removal.
REMOVING THE NMD-100:
1. Open the lower right rear cabinet door (2-door) or lower cabinet door (1-door).
2. EXTEND DISPENSER TRAY:
Pull up on the tray locking pin and extend the tray fully.