User Manual User guide

88
moDel rl/Ft5000
XP
USer mAnUAl w/PriSm
tm
nDc emUlAtion
enter key A
AcceSS inStrUctionS:
1. From the DiAgnoSticS screen, select the key mAnAgement option by
pressing number <3> on the keypad.
2. Use the keypad to log into the key mAnAgement menU. enter the USer
1 PASSworD and then press the <Enter> key. Enter the USer 2 PASS-
worD and then press the <Enter> key.
3. After logging into the key mAnAgement menU, select the enter key
A option by pressing the number <1> on the keypad.
DeScriPtion:
The enter key A option is used as the Master PIN key. A new encrypted
PIN key can be downloaded from the host computer using this key. Once
the new PIN key is loaded, the A key is no longer used. Any new PIN key
downloaded from the host will be encrypted using the current PIN working
key. The PIN Master key is made up of hexadecimal characters ( numbers
0 - 9 and the letters A, B, C, D, E, F). To enter the A Key (PIN Master) key:
1. Press <1> on the keypad. A DES key input box (max length - 32) will
be displayed for a user to enter Part 1 and Part 2 of key A (PIN Master
Key). There are also four (4) function keys (F5 - F8) and an on-screen
keypad are displayed. The on-screen keypad corresponds to the terminal
keypad.