User Manual User guide

triton DiAgnoSticS
73
teSt DiSPenSe
AcceSS inStrUctionS:
1. From the DiAgnoSticS screen, select the cASh DiSPenSer option by
pressing number <1> on the keypad.
2. From the cASh DiSPenSer screen, select the teSt DiSPenSe option by
pressing number <3> on the keypad.
DeScriPtion:
The teSt DiSPenSe command allows the user to dispense note(s) from each
installed and operational cassette into the reject cassette. This test exercises
the dispenser mechanism without sending notes to the exit.
The
lock All cASSetteS function will automatically be performed rst to
ensure that all cassettes are locked. Next, the cassettes’ information will be
retrieved. The Test Dispense can only be exercised on the cassettes installed.
Once the cassette information is retrieved, the user will be prompted to enter
the number of note(s) to be dispensed from cassette A through D, if applica-
ble. The values for the number of notes are 1 to 5. If the user enters a number
greater than 5, it will automatically default to 5.
Press the number <1> on the keypad and enter the desired value. Press the
<Enter> key. Repeat for the remaining cassettes that are available.
Next, press the number <5> on the keypad to
PerForm teSt. The dispenser
will dispense the note(s) from the cassette(s) into the reject cassette. The
progress bar will be displayed while the operation is being performed.
When the test is completed, the user will be prompted to either perform an-
other test or exit and go back to the Cash Dispenser menu.