User Manual Instruction Manual

112
MODEL RL/FT5000
XP
USER MANUAL
GENERAL SETTINGS
ACCESS INSTRUCTIONS:
1. From the MAIN MENU screen, select the TERMINAL CONFIGURATION option
by pressing number <6> on the keypad.
2. From the TERMINAL CONFIGURATION screen, select the CASH DISPENSER
SETUP option by pressing number <4> on the keypad.
3. From the CASH DISPENSER SETUP screen, select the GENERAL SETTINGS
option by pressing number <1> on the keypad.
DESCRIPTION:
The GENERAL SETTINGS option allows the terminal operator to perform the fol-
lowing functions:
1. REPORT ERROR STATUS AS LOGICAL. This function allows user to set the
cassette status reporting option. When enabled, the cassette status will
be reported to the host application per logical cassettes. When disabled,
the cassette status will be reported per physical cassettes. Press <1> on
the keypad to toggle between enabled (check) or disabled (uncheck).
2. TRAP STATUS THRESHOLD (CONSECUTIVE SHUTTER ERRORS). This function
allows user to set the value of the trap status threshold. During the online
transactions, the shutter may fail to open. If the number of consecutive
shutter failures is greater than or equal to the trap status threshold, the
Prism software reports the “Shutter” status to the host application. The
default status is set to two (2). To enter a value, press <2> on the keypad
and enter the desired value. Press <Enter>. The trap status minimum/
maximum values are 0-99.