User Manual User guide
18
MODEL FT5000 (X2) USER MANUAL
CASSETTE CLOSE PROCEDURES
Follow Access instructions to enter MANAGEMENT FUNCTIONS. Select TERMINAL CLOSE FUNCTIONS. Select
CASSETTE CLOSE.
Select cassette(s) to Close. A check mark ( √ )
identifies which cassette(s) are selected. Press
<ENTER>.
After cassette(s) have been reinserted in the
dispenser, press <ENTER>.
Note: For an NMD-50/100 dispenser installed, wait
for the cassettes to LOCK (this is done automatically).
Press <Enter> if applicable.
A Close report is displayed to be printed or
saved. This operation will reset the number of bills
in the cassette(s) to ZERO (0). Press <ENTER>.
Remove and Replenish the selected cassette(s).
Procedures for cassette replenishment
start on page 20.
Note: For an NMD-50/100 dispenser installed, wait
for the cassettes to UNLOCK (this is done automatically).
Place selected cassette(s) IN SERVICE. Press
<ENTER>. Note: The NMD-50/100 cassettes Must be
Locked and In Service for normal operation.
Enter Cassette Quantity (number of notes, NOT
value) for the selected cassette(s). Press <ENTER>
to accept entry. Repeat for each selected cassette.
A Trial Cassette Close report automatically is
displayed to be printed or saved. Print and retain a
copy for starting point reference. Press <ENTER> to
return to Close functions.