User guide
TRITON SYSTEMS, INC.
SECTION 5 - MANAGEMENT FUNCTIONSOPERATION MANUAL - MODEL 97XX-Series
5-114
9700-SERIES
9705-SERIES
9710-SERIES
9750-SERIES
DATAPAK ACCESS CODE
FACTORY DEFAULT: N/A
ACCESS INSTRUCTIONS:
1. Select TERMINAL CONFIGURATION from the MANAGEMENT
FUNCTIONS menu.
2. Select SET TERMINAL PARAMETERS.
3. Select TELEPHONE.
4. Select DATAPAK ACCESS CODE.
DESCRIPTION:
NOTE: This feature is only available for Canadian-region ATMs.
This function allows you to enter the DATAPAK ACCESS CODE,
and to turn the DataPak feature On or OFF. The DATAPAK AC-
CESS CODE is provided by the DataPak processing organization,
and is an identification number which enables the DataPak pro-
cessing organization to correctly identify and route data traffic be-
tween the terminal and the transaction processor.
The current state of the DATAPAK ACCESS CODE feature is shown
as either ON or OFF in the label on the left-hand side of the dis-
play. Press the button next to this label to toggle the state of the
feature between ON and OFF.
IMPORTANT: When using the DATAPAK communications proto-
col, ensure the terminal’s Primary and Backup Telephone Num-
bers are configured to dial the DataPak processing organization
(NOT the transaction processor!).
E
RROR CONDITIONS:
If a DATAPAK-based communications network is being used, the
DATAPAK ACCESS CODE feature must turned ON and the code
must be entered correctly to enable message traffic between the
ATM and the processor to take place.