S TTTTTTTTT UUUU TUTTTTTTT --- (Ignore any additional characters, if present.)
Lid Solenoid Status Sensor [ ‘0’ = Solenoid Not Activated,
‘1’ = Solenoid Activated ]
Cassette Lid/Lock Sensor [ ‘0’ = Lid Closed and Locked,
‘1’ = Lid Not Closed ]
RC Shutter Sensor Stack Retract Pos.
[ ‘0’ = Sensor Not Obstructed, ‘1’ = Sensor Obstructed,
‘2’ = Sensor Error ]
RC Shutter Sensor Stack Accept Pos.
[ ‘0’ = Sensor Not Obstructed, ‘1’ = Sensor Obstructed,‘2’ = Sensor Error ]
RC Shutter Sensor Single Accept Pos.
[ ‘0’ = Sensor Not Obstructed, ‘1’ = Sensor Obstructed, ‘2’ = Sensor Error ]
RC Shutter Sensor Closed Pos.
[ ‘0’ = Sensor Not Obstructed, ‘1’ = Sensor Obstructed, ‘2’ = Sensor Error ]
RC Present Sensor [ ‘0’ = Cassette Not Present, ‘1’ = Cassette Present. ]
Note Diverter (ND) Reject Exit Sensor Calibration Value [ 0-7]
ND Reject Exit Sensor [ ‘0’ = Sensor Not Obstructed, ‘1’ = Sensor Obstructed,
‘2’ = Sensor Error, ‘3’ = Sensor Warning ]
BCU Empty Sensor Calibration Value [ 0-31]
BCU Exit Sensor Calibration Value [ 0-31]
Shutter Close Sensor [ ‘0’ = Shutter Closed, ‘1’ = Shutter Not Closed,
‘2’ = Sensor Error, ‘-’ = Sensor Not Present ]
Shutter Open Sensor [ ‘0’ = Shutter Closed, ‘1’ = Shutter Not Closed,
‘2’ = Sensor Error, ‘-’ = Sensor Not Present ]
BCU Retract Sensor [ ‘0’ = BCU Not at Sensor, ‘1’ = BCU at Sensor, ‘2’ = Sensor Error ]
BCU Reject Sensor [ ‘0’ = BCU Not at Sensor, ‘1’ = BCU at Sensor, ‘2’ = Sensor Error ]
BCU Home Sensor [ ‘0’ = BCU Not at Sensor, ‘1’ = BCU at Sensor, ‘2’ = Sensor Error ]
BCU Rear Service Deliver Position Sensor [ ‘0’ = Shutter Closed, ‘1’ = Shutter Not Closed,
‘2’ = Sensor Error, ‘-’ = Sensor Not Present ]
BCU Front Service Deliver Position Sensor [ ‘0’ = Shutter Closed, ‘1’ = Shutter Not Closed,
‘2’ = Sensor Error, ‘-’ = Sensor Not Present ]
BOU Empty Sensor [ ‘0’ = Sensor Not Obstructed, ‘1’ = Sensor Obstructed,
‘2’ = Sensor Error, ‘3’ = Sensor Warning ]
BOU Exit Sensor [ ‘0’ = Sensor Not Obstructed, ‘1’ = Sensor Obstructed,
‘2’ = Sensor Error, ‘3’ = Sensor Warning ]
General Status Code [ ‘0’ = OK ]
Notes:
‘ND’ Stands for Note Diverter.
‘RC’ Stands for Reject Cassette.