Manual

SECTION 9 - INTERPRETING RETURN CODES
9-7
MULTI-CASSETTE CASH DISPENSER OPERATION MANUAL
TRITON SYSTEMS, INC.
M
ODELS 9650/9670
INTERPRETING THE FEED CHANNEL RETURN CODE
S TTTTTTTTTTT UUUU VVV HHH CCC DDDD --- (Ignore any additional characters, if present.)
Denomination Code
1
Currency Code
Note Size: Horizontal
Note Size: Vertical
Shutter Sensors Calibration Value [ 0-3 ]
2
Pressure Sensor Calibration Value [ 0-3 ]
Empty Sensor Calibration Value [ 0-7 ]
Exit Sensor Calibration Value [ 0-7 ]
3
NC Lid Solenoid Status Sensor [ 0 = Solenoid Not Activated, 1 = Solenoid Activated ]
NC Shutter Solenoid Status Sensor [ 0 = Solenoid Not Activated, 1 = Solenoid Activated ]
Cassette Lid/Lock Sensor [ 0 = Lid Closed and Locked, 1 = Lid Not Closed ]
Cassette Low Level Sensor [ 0 = Low Level, 1 = Not Low Level ]
4
Cassette Present Sensor [ 0 = Cassette Not Present, 1 = Cassette Present ]
NC Shutter Sensor 3 [ 0 = Sensor Not Obstructed, 1 = Sensor Obstructed ]
5
NC Shutter Sensor 2 [ 0 = Sensor Not Obstructed, 1 = Sensor Obstructed ]
5
NC Shutter Sensor 1 [ 0 = Sensor Not Obstructed, 1 = Sensor Obstructed ]
5
Pressure Sensor [ 0 = Low Feed Pressure, 1 = Normal Feed Pressure ]
Empty Sensor [ 0 = Sensor Not Obstructed, 1 = Sensor Obstructed ]
Exit Sensor [ 0 = Sensor Not Obstructed, 1 = Sensor Obstructed ]
General Status Code [ 0 = OK ]
NOTES:
1.) First three characters are Denomination Code (ex. 010 = $10.00). Fourth position is a Variant code character
that defines a currency version or variation, if applicable.
2.) This parameter is currently not implemented.
3.) The normal range for the Exit Sensor Calibration Value is 2-4. Higher values mean a dirtier sensor.
4.) This is a warning status only, when active.
5.) The normal status pattern for this group of three Sensors is 101.
NC Stands for Note Cassette.
When a Note Cassette is not present the positions related to the cassette will be reported as -.