Owner manual
5-16
SECTION 5 - MANAGEMENT FUNCTIONS
SINGLE-CASSETTE CASH DISPENSER OPERATION MANUAL
TRITON SYSTEMS, INC.
MODELS 9600/9601/9620/9621
FUNCTION: STATUS
FACTORY DEFAULT: N/A
ACCESS INSTRUCTIONS:
1.) Select DIAGNOSTICS from the MANAGE-
MENT FUNCTIONS screen.
2.) Select the STATUS option.
DESCRIPTION:
The STATUS command is used to check the status of four functional areas of the dispensing
mechanism. These areas are the current Status of Count Sensors, the current Double Detect
status, the current average thickness of the documents being dispensed, and the current average
length of the documents being dispensed. Any of the following sets of return codes will indicate
that all of the areas are operating normally:
1.) ‘40 50 40 36’
2.) ‘50 50 40 36’
3.) ‘44 50 40 36’
4.) ‘54 50 40 36’
The cancel button must be pressed to return to the diagnostic’s menu.
ERROR CONDITIONS:
If any code other than what is indicated above is displayed contact your service provider for
assistance.