Owner Manual
5
TDM-100/150 BASE PLATE UPGRADE PROCEDURES
REPLACING THE BASE PLATE, DETENT CLIPS, DIVERTER FASTENERS
The following procedures apply to both TDM dispensers (100/150). The TDM-150 has two (2) additional torx screws that have to
be removed from each side. The following steps will reference the TDM-100.
TDM-100
TDM-150
Figure 2. Torx/phillips screws location.
1. Place the dispenser on its side as shown in Figure 1. Using the #20 torx driver, remove the three (3) bottom torx screws. Set
screws aside.
2. Turn the dispenser over on its other side as shown in Figure 2. Remove the two (2) bottom torx screws. Set screws aside. Using
a phillips screwdriver, remove the two (2) phillips screws that secure the belt cover and grounding harness. Remove the belt
cover and set screws aside.
Figure 1. Torx screws location.
3. Turn the dispenser over so that the bottom plate is facing up as shown in Figure 3. Remove the bottom torx screw shown. Set the
screw aside.
Figure 3. Bottom Torx screw location.
Note
This screw is slightly different from the other ones
removed. When reassembling the new base plate,
ensure this screw is placed in the proper location.
Belt cover