Owner Manual
3
T5 PCI-EPP ConvErsIon ProCEdUrEs
InTrodUCTIon
This guide covers the steps for converting X-Scale/X2 terminals shipped with VISA® Encrypting PIN Pads (VEPP) to a T5 PCI-
certied EPP. These procedures include a list of tools, hardware, and software required for the conversion.
sCoPE
These procedures apply to all Triton certied service personnel involved in the process of maintaining or converting Triton ATMs.
** IMPORTANT **
BEFORE
ProCEEdIng wITH THE kIT HardwarE InsTallaTIon, THE TERMINAL SOFT-
WARE
InClUdEd In kIT (Cd), MUST BE LOADED FIRST To THE TErMInal. THE Pro-
CEdUrE For loadIng soFTwarE Is loCaTEd In aPPEndIx a.
THE CUrrEnT TErMInal ParaMETErs and joUrnal rECords will BE aFFECTEd or losT. BEForE
ProCEEdIng wITH THE soFTwarE UPload, IT Is HIgHly rECoMMEndEd THaT yoU
FIrsT - savE TErMInal ParaMETErs and joUrnal rECords To an ExTErnal
sToragE dEvICE (UsB THUMBdrIvE). THE ProCEdUrEs For savIng and rEsTorIng TErMInal
ParaMETErs and savIng joUrnal rECords arE loCaTEd In aPPEndIx a.
noTE: joUrnal rECords May also BE savEd UsIng TrITon ConnECT.
nExT, PRINT THE ConFIgUraTIon sUMMary. yoU May also wanT To PrInT THE
joUrnal rECords as wEll.
oPEn THE “soFTwarE load FIlEs” FoldEr on THE Cd. loCaTE THE aPPlICaBlE CoUnTry
FoldEr and dIsPlay sIzE. CoPy all soFTwarE FIlEs FroM THIs FoldEr To yoUr UsB sToragE
dEvICE. x-sCalE soFTwarE Is IdEnTIFIEd wITH a .TlF ExTEnsIon. x2 TErMInal soFTwarE
Is IdEnTIFIEd wITH a .TFV ExTEnsIon.
NOTE: The software version required for the T5 PCI-EPP upgrade must be “2.2.1” or
greater. If the current version software loaded on your terminal is equal to or greater
than the version listed (2.2.1), you do not need to load software.
MOST IMPORTANT NOTE: This version of software changes the requirement to enter
6 (six) zeros before changing the keypad passwords. The keypads are shipped with NO
PREASSIGNED PASSWORDS. IF YOU ENTER 6 (SIX) ZEROS AS WITH PREVIOUS
VERSIONS OF SOFTWARE, THAT WILL BE THE PASSWORD AND CANNOT BE
CHANGED IN THE FIELD.
NoTE: The .PDF FIlEs (“rElEasE noTEs”) rEFEr To THE soFTwarE load FIlEs. rECoM-
MEnd rEadIng THEsE doCUMEnTs PrIor To UPgradIng TErMInal soFTwarE.